<rfc category="info" docName="draft-dugeon-pce-ted-reqs-03" ipr="trust200902">
  <front>
    <title abbrev="PCE TED Req.">Path Computation Element (PCE) Database
    Requirements</title>

    <author fullname="Olivier Dugeon" initials="O.D." surname="Dugeon">
      <organization>Orange</organization>

      <address>
        <postal>
          <street>2, Avenue Pierre Marzin</street>

          <city>Lannion</city>

          <code>22307</code>

          <country>France</country>
        </postal>

        <email>olivier.dugeon@orange.com</email>
      </address>
    </author>

    <author fullname="Julien Meuric" initials="J.M." surname="Meuric">
      <organization>Orange</organization>

      <address>
        <postal>
          <street>2, Avenue Pierre Marzin</street>

          <city>Lannion</city>

          <code>22307</code>

          <country>France</country>
        </postal>

        <email>julien.meuric@orange.com</email>
      </address>
    </author>

    <author fullname="Richard Douville" initials="R.D." surname="Douville">
      <organization>Alcatel-Lucent</organization>

      <address>
        <postal>
          <street>Route de Villejust</street>

          <city>Nozay</city>

          <region/>

          <code>91620</code>

          <country>France</country>
        </postal>

        <email>richard.douville@alcatel-lucent.com</email>
      </address>
    </author>

    <author fullname="Ramon Casellas" initials="R.C." surname="Casellas">
      <organization>CTTC</organization>

      <address>
        <postal>
          <street>Av. Carl Friedrich FGauss n7</street>

          <city>Castelldefels</city>

          <region>Barcelona</region>

          <code>08860</code>

          <country>Spain</country>
        </postal>

        <email>ramon.casellas@cttc.es</email>
      </address>
    </author>

    <author fullname="Oscar Gonzalez de Dios" initials="O.G.D."
            surname="Gonzalez de Dios">
      <organization>Telefonica Investigacion y Desarrollo</organization>

      <address>
        <postal>
          <street>C/ Emilio Vargas 6</street>

          <city>Madrid</city>

          <code/>

          <country>Spain</country>
        </postal>

        <email>ogondio@tid.es</email>
      </address>
    </author>

    <date day="14" month="February" year="2014"/>

    <area>Routing Area</area>

    <workgroup>Path Computation Element Working Group</workgroup>

    <keyword>Draft</keyword>

    <abstract>
      <t>The Path Computation Element (PCE) working group (WG) has produced a
      set of RFCs to standardize the behavior of the Path Computation Element
      as a tool to help MPLS-TE and GMPLS LSP tunnels placement. In the PCE
      architecture, a main assumption has been done concerning the information
      that the PCE needs to perform its computation. In a fist approach, the
      PCE embeds a Traffic Engineering Database (TED) containing all pertinent
      and suitable information regarding the network that is in the scope of a
      PCE. Nevertheless, the TED requirements as well as the TED information
      have not yet been formalized. In addition, some recent RFC (like the
      Backward Recursive Path Computation procedure or PCE Hierarchy) or WG
      draft (like draft-ietf-pce-stateful-pce ...) suffer from a lack of
      information in the TED, leading to a non optimal result or to some
      difficulties to deploy them. This memo tries to identify some Database,
      at large, requirements for the PCE. It is split in two main sections:
      the identification of the specific information to be stored in the PCE
      Database and how it may be populated.</t>
    </abstract>

    <note title="Requirements Language">
      <t>The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
      "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
      document are to be interpreted as described in <xref
      target="RFC2119">RFC 2119</xref>.</t>
    </note>
  </front>

  <middle>
    <section title="Problem Statement">
      <t>Looking to the different RFCs that describe the PCE architecture and
      in particular <xref target="RFC4655">RFC 4655</xref>, <xref
      target="RFC5440">RFC 5440</xref>, <xref target="RFC5441"> RFC
      5441</xref> and <xref target="RFC6805">RFC 6805</xref>, the Path
      Computation Element (PCE) needs to acquire a set of information that is
      usually store in the Traffic Engineering Database (TED) in order to
      perform its path computation. Even if intra-domain topology acquisition
      is well documented and known (e.g. by listening to the IGP-TE protocol
      that runs inside the network), inter-domain topology information, PCE
      peer address, neighbor AS, existing MPLS-TE tunnels... that are
      necessary for the Global Concurrent Optimization, Backward Recursive
      Path Computation (BRPC) and the Hierarchical PCE are not documented and
      not completely standardized.</t>

      <t>The purpose of this memo is to inventory the required information
      that should be part of the PCE Database and the different mechanisms
      that allow an operator to populate it.</t>

      <section title="PCE Assumption and Hypothesis">
        <t>In some cases, both the path computation and the Database
        operations are slightly coupled: border node identification, endpoint
        localization, TE-LSP learning and domain sequence selection... to name
        a few in which an IGP-based TED may not be sufficient. It is also
        important to differentiate several environments with different
        requirements, especially for the multi-domain problem. The PCE is
        scoped for any kind of network, from transmission networks (TDM/WDM)
        with a rather limited number of domains, few interconnections, and few
        confidentiality issues; transmission networks with a large number of
        domains; MPLS networks with several administrative domains; and big
        IP/MPLS networks with a large number of domains with peering
        agreements. For each of them, a different solution for the
        multi-domain path computation may apply. A solution may not be
        scalable for one, but perfectly suitable for another.</t>

        <t>Up to now, PCE WG has based its work and standard on the assumption
        and hypothesis that the TED contains all pertinent information
        suitable for the PCE to compute an optimal TE-LSP placement, over one
        or several domains a PCE has visibility on or over a set of
        PCE-capable domains (e.g. using BRPC procedure). We could identify
        several major sources of information for the TED:</t>

        <t><list style="symbols">
            <t>The intra-domain routing protocol like OSPF-TE or IS-IS-TE
            (including extensions for inter-domain links),</t>

            <t>The inter-domain routing protocol, i.e. BGP,</t>
            
            <t>TED synchronization protocols, e.g., BGP-LS,</t>

            <t>Through manual and or management configuration.</t>
          </list>If the first source gives a precise and synchronize view of
        the controlled network, i/eBGP typically just provides network
        reachability with only one AS path (unless using recent add path
        option). Now, the TE information traditionally flooded by the IGPs can
        also be communicated through a BGP sessions, as described in <xref
        target="I-D.ietf-idr-ls-distribution">"North bound distribution of
        Link-State and TE Information using BGP"</xref>. Nevertheless, to
        optimize inter-domain path computation, route diversity and a minimum
        set of Traffic Engineering information about the remote domains could
        be helpful. Despite that it is possible to re-announce TE-LSP in the
        IGP-TE, the PCE needs also to have a precise knowledge of previous
        TE-LSP, not only for its stateful version [<xref
        target="I-D.ietf-pce-stateful-pce">PCEP Extensions for Stateful
        PCE]</xref>, but also when performing a global concurrent optimization
        <xref target="RFC5557">RFC5557</xref> of the previous TE-LSPs place on
        a given domain.</t>

        <t>The last source of information, mainly static, information can be
        the management plane, e.g. using SNMP, Netconf, CLI... So, it is necessary to
        classify the source of information by their frequency of update:
        static or dynamic, e.g. a domain ID is unlikely to change, while
        unreserved bandwidth of a link may be continuously changing. Finally,
        all sources of information are pertinent and must be take into account
        to fulfil the PCE database at large.</t>

        <t>In this document, PCE Data Base (namely PCE-DB in the rest of the
        document) is used not only to refer to the usual notion of Traffic
        Engineering Database information, but also encompasses all relevant
        information. E.g., the phrase also refers to the list of TE-LSPs running in
        the domain, sometimes referred as LSP-DB in other documents. Note that this
        PCE-DB may be implemented over multiple independant DBs.</t>
      </section>

      <section title="Terminology">
        <t>ABR: Area Border Routers. Routers used to connect two IGP areas
        (areas in OSPF or levels in IS-IS).</t>

        <t>ASBR: Autonomous System Border Router. Router used to connect
        together ASes of the same or different service providers via one or
        more inter-AS links.</t>

        <t>AS: Autonomous System</t>

        <t>Boundary Node (BN): a boundary node is either an ABR in the context
        of inter-area Traffic Engineering or an ASBR in the context of
        inter-AS Traffic Engineering.</t>

        <t>Domain: an Autonomous System or IGP Area</t>

        <t>Entry BN of domain(n): a BN connecting domain(n-1) to domain(n)
        along a determined sequence of domains.</t>

        <t>Exit BN of domain(n): a BN connecting domain(n) to domain(n+1)
        along a determined sequence of domains.</t>

        <t>Inter-area TE LSP: A TE LSP that crosses an IGP area boundary.</t>

        <t>Inter-AS TE LSP: A TE LSP that crosses an AS boundary.</t>

        <t>IGP-TE: Interior Gateway Protocol with Traffic Engineering support.
        Both OSPF-TE and IS-IS-TE are identified in this category.</t>

        <t>PCE: Path Computation Element. An entity (component, application,
        or network node) that is capable of computing a network path or route
        based on a network graph and applying computational constraints.</t>

        <t>PCE(i) is a PCE with the scope of domain(i).</t>

        <t>PCE-DB: Path Computation Element Data Base</t>

        <t>TED: Traffic Engineering Database.</t>
      </section>
    </section>

    <section title="PCE DataBase Requirements">
      <t>This section made a first inventory of the main requirements of the
      PCE Data Base in term of information that the database should
      contains.</t>

      <section title="Intra-Domain">
        <t>This section describes the Intra-domain information that are
        suitable for the PCE Database including both MPLS and GMPLS.</t>

        <section title="MPLS">
          <t>A PCE is allowed to compute paths in one or several domains. Such
          PCE MUST be aware of the precise details of the network topology (or
          topologies) in order to compute optimal TE-LSP placements. The
          information needed in this case includes:<list style="symbols">
              <t>List of Internal Nodes identified by a reachable address: All
              nodes of the networks with a particular mention for border node
              (see next section),</t>

              <t>List of Internal Links that rely nodes (both internal and
              border nodes),</t>

              <t>Traffic Engineering information of the different links i.e.
              <xref target="RFC3630">RFC 3630</xref> and <xref
              target="RFC5305">RFC 5305</xref>(with e.g. recent metric
              extensions proposal <xref
              target="I-D.ietf-ospf-te-metric-extensions">OSPF Traffic
              Engineering (TE) Metric Extensions</xref>)</t>

              <t>Traffic Engineering information of the nodes.</t>
            </list></t>

          <t>The information above mentioned is usually exchanged using the
          IGP-TE protocol (OSPF-TE or IS-IS-TE).</t>
        </section>

        <section title="GMPLS">
          <t>When dealing with a (G)MPLS network, the PCE MUST be aware of the
          complementary information:</t>

          <t><list style="symbols">
              <t>Traffic Engineering information with GMPLS extensions of the
              different links i.e. <xref target="RFC4203">RFC 4203</xref> and
              <xref target="RFC5307">RFC 5307</xref>,</t>
            </list>To be completed latter</t>
        </section>
      </section>

      <section title="Inter-Domain">
        <t>A PCE can also be allowed to take part to inter-domain path
        computation (e.g in per-domain path computation, BRPC or H-PCE
        relationship). Some inter-domain information is mandatory when
        operator intend to use the PCE to compute Inter-AS TE LSP path that
        cross domain boundary. For that purpose, the PCE-DB SHOULD contains
        all information that allow the PCE to determine the optimal
        inter-domain path for the TE-LSP computation, which includes:</t>

        <t><list style="symbols">
            <t>Border Nodes (BNs) of the domain. A distinction could be made
            between ALL domains and Neighbor domains only. In the document, we
            consider ALL domains to be sure that the PCE has the complete
            visibility of the path diversity.</t>

            <t>Links between BN, i.e. links between BN (n) to BN (n+1),
            including Traffic Engineering information,</t>

            <t>Traffic Engineering performance between BN (n) to give
            performance indication on remote domain n (See section 3.2 on
            PCE-DB model for the inter-domain part)</t>

            <t>PCE (i) peer address associated with the domain number and
            identity of the remote domain (i),</t>
          </list><xref target="RFC5316">RFC 5316</xref> for IS-IS and <xref
        target="RFC5392">RFC 5392</xref> for OSPF help to provide required
        PCE-DB information in the case of inter-domain. PCE-DB can also
        contain information about virtual links and abstract information.</t>
      </section>

      <section title="TE LSPs">
        <t>For stateful operation and Global Concurrent Optimization, the
        PCE-DB should also contain information on TE-LSPs already enforce in
        the controlled domain. If some TE-LSP tunnels could be re-announce in
        the IGP-TE, the PCE could not learn from the IGP-TE all details of all
        TE LSPs: if TE information is known, detail of the ERO is lost as well
        as initial QoS parameters. The following information will be useful
        for the PCE-DB to describe the TE-LSP:</t>

        <t><list style="symbols">
            <t>Explicit Route Object (ERO),</t>

            <t>End-points objects,</t>

            <t>Initial and actual Metric objects, including extend metrics
            such as delay, jitter, packet loss,</t>
          </list></t>

        <t>Recent <xref target="I-D.ietf-pce-stateful-pce">PCEP Extensions for
        Stateful PCE</xref> provide new PCEP message to convey these kind of
        information. However, this capacity could be used disregarding the
        behavior (stateless or stateful) of the PCE. Indeed, if it is
        mandatory for stateful PCE, these information are of great importance
        then performing Global Concurrent Optimization, even with a stateless
        PCE.</t>
      </section>

      <section title="Operational Information">
        <t>This part of the TED contains all others information, and in
        particular the PCE policy, pertinent for the PCE to compute TE LSP
        path but that are provided through the management system.</t>
      </section>
    </section>

    <section title="PCE-DB model">
      <t>This section inventory the database model(s) to store pertinent
      information regarding the different source of information.</t>

      <section title="Intra-domain">
        <section title="MPLS">
          <t>For intra-domain, there is no need to specify a particular model
          or schema for the PCE-DB. Indeed, the model is directly based on the
          IGP-TE. Of course there is a difference between IS-IS and OSPF, but
          TE Link state are more of less similar in term of conveyed
          information and database description. No particular requirements are
          necessary as this stage.</t>
        </section>

        <section title="GMPLS">
          <t>To be provided later.</t>
        </section>
      </section>

      <section title="Inter-domain">
        <t>Contrary to intra-domain where the PCE known the exact details of
        the underlying network, it is not possible to achieve a similar detail
        level for the inter-domain. And not only for scalability reasons, but
        mostly for confidentiality of the networks. This memo propose a basic
        schema that allows PCE to known sufficient details about the remote
        domain while keeping confidential the internal information. For this
        purpose, we propose to describe a domain as a "Grey-Box" with inputs
        and outputs that correspond to the Border Nodes (BNs). Then Grey-Boxes
        are interconnected through inter-domain links between the BNs. Then,
        suitable performance indicators are given to cross the Grey-Boxes from
        an input BN to and output BN. Figure below gives as example of such
        model.</t>

        <t><figure>
            <artwork align="center"
                     name="Example of the representation of 2 domains with Black-box model"><![CDATA[
          +----------------+          +----------------+
          |  Domain (B)    |          |  Domain (C)    |
Inter     |                |  Inter   |               (BN)-- Inter
Domain --(BN)              |  Domain  |                |     Domain
Link      |              (BN)--------(BN)             (BN)-+ Links
          |                |  Link    |                |   |
          +-----(BN)-------+          +----------------+   |
                 |                                         |
                 | Inter-domain Link                       |
          +-----(BN)-------+          +------(BN)------+   |
          |  Domain (A)    |          |  Domain (D)    |   |
Inter     |                |  Inter   |               (BN)-+ Inter
Domain --(BN)              |  Domain  |                |     Domain
Link      |              (BN)--------(BN)             (BN)-- Links
          |                |  Link    |                |
          +-----(BN)-------+          +----------------+
                 |
                 | Inter-domain Link


Example of the representation of 3 domains with the Grey-Box model 
  ]]></artwork>
          </figure></t>

        <t>Domain C is reachable from domain A through domain B or domain D.
        For a PCE, with such model, it becomes easy to compute a constraint
        shortest path by combining the resources availability on Inter-Domain
        links and cost to cross the different domain. For example, with these
        figures (note that we take only one measured to illustrate the purpose
        and that multiple constraints are used in reality):</t>

        <t><list style="symbols">
            <t>Crossing B cost 100, D cost 50, C cost 75, A cost 50</t>

            <t>Inter-domain links costs: A to B = 10, B to C = 20, A to D =
            10, D to C = 50</t>
          </list>PCE A could not choose between B or D as the Inter-domain
        link costs are equal. With the proposed model, it could compute that
        going through B cost 130 (= 10 + 100 20) and through D cost 110 (= 10
        + 50 + 50) and choose D path even if the last Inter-domain links is
        costly.</t>

        <t>Today, when trying to compute an inter-domain TE LSP, the PCE may
        failed in its computation and used crank back facilities to find a
        suitable path. With such inter-domain information, a PCE could look
        into the different inter-domain path (as the sum of inter-domain links
        and Grey-Box crossing performances) and select the most suitable one
        regarding the PCReq avoiding crank back and achieve possibly, better
        results as it explore all possible inter-domain paths.</t>

        <t>If the inter-domain links between BN that connect the Grey-Boxes
        description are covered (see section 2.2), it is not the case for the
        internal links between BNs inside the Grey-Box.</t>
      </section>
    </section>

    <section title="PCE-DB Population">
      <t>This section aims to provide best current practices when mechanisms
      are well-known and some hints when standard solutions exist to populate
      the PCE TED, and so give directions to extend them. In particular, we
      aim at providing input on whether the TED gets the information from the
      routing protocol and how it gets it, which specific routing protocols
      are suited, whether it gets it from an NMS, at what frequency the TED is
      updated... and if it needs extra information.</t>

      <section title="Intra-domain">
        <t/>

        <section title="MPLS">
          <t>As the TED mainly contains the intra-domain topology graph, it is
          RECOMMENDED to link the PCE with the underlying IGP-TE (OSPF-TE or
          IS-IS-TE routing protocol). By adding the PCE into the IGP-TE
          routing intra-domain, it is possible to listen to the routing
          protocol and then acquired the complete topology graph as well as
          let the PCE announce itself (see RFC5088 and RFC5089). In addition,
          the TED will synchronize as fast as the routing protocol converges
          like any router in the domain. Best current practices are also of
          interest when a PCE compute path that spawn to several area /
          region. In that case, the PCE must be aware of the topology details
          of each area / region.</t>

          <t>Note that linking the PCE with the underlying IGP-TE may also be
          accomplished through receiving BGP-LS updates as described in <xref
          target="I-D.ietf-idr-ls-distribution">"North bound distribution of
          Link-State and TE Information using BGP"</xref>. Although joining
          the IGP is good enough, BGP-LS is not precluded for use intra-domain
          and can be a nice way to have a uniform mechanism to acquire the TED
          e.g. from a Route Reflector that also listen to the IGP.</t>

          <t>In addition, management tools may be used to complement the
          topology graph provided by the routing protocol.</t>
        </section>

        <section title="GMPLS">
          <t>To be provided later.</t>
        </section>
      </section>

      <section title="Inter-Domain">
        <t>If for inter-area aspect of the inter-domain, actual IGP protocol
        provide in general the aforementioned information without any
        particular extension, this is not the case for the inter-as scenario
        and sometimes an issue for inter-area.</t>

        <t>First of all, RFC 5316 or RFC 5392 MUST be activated in the IGP-TE
        (respectively in IS-IS-TE or OSPF-TE) in order to advertise TE
        information on the inter-domain links. This gives the advantage for
        the PCE to determine what could be feasible, during path computation,
        on the peering links.</t>

        <t>In MPLS, AS path and network reachability are obtained from BGP and
        routing tables. In addition, domain or sequence path could be
        specified in the PCE Request. However, when inter-domain path is not
        known or could not retrieve from an external entities, it could be of
        interest for a PCE to have the possibility to compute the inter-domain
        path prior to the intra-domain part. Again, the PCE needs
        corresponding information in its PCE-DB. But, it is not
        straightforward to collect route diversity or TE information (i.e.
        bandwidth, transit delay, packet loss ratio, jitter ...) on a remote
        domain. Of course, for confidentiality and scalability issues, the PCE
        MUST NOT learn all details of the remote TED, it just needs an
        abstract view like proposed in <xref
        target="I-D.farrel-interconnected-te-info-exchange">"Problem Statement
        and Architecture for Information Exchange Between Interconnected
        Traffic Engineered Networks"</xref>.</t>

        <t>Right now, we have identified several methods, which have been
        tested to fill in the PCE-DB with this kind of information:<list
            style="symbols">
            <t>Use of the management plane;</t>

            <t>Use of the <xref target="I-D.ietf-idr-ls-distribution">"North
            bound distribution of Link-State and TE Information using
            BGP"</xref> proposal to exchange TE information about the remote
            domain;</t>

            <t>Use of PCNtf message to convey, inside vendor attribute (but in
            an extended way), TE information of remote domain between PCE</t>
          </list>As well as some potential alternative mechanisms that would
        need more standardization effort:</t>

        <t><list style="symbols">
            <t>A Hierarchical TE that could help to advertise, at the AS
            level, TE information on an abstract view of the remote AS
            topology;</t>

            <t>A PCEP extension to convey such TE information to the remote
            PCE.</t>
          </list></t>

        <section title="Information exchange">
          <t>The force of PCE is to be aware of the complete topology of the
          underlying network where it is connected. With such knowledge, it
          could place efficiently the tunnel even if it not follows the route
          computed by the IGP routing protocol. Same principles apply also for
          the inter-domain. But, in the Internet today, BGP summarize the
          route and the PCE should not be aware of the route diversity. In
          particular, it could not choose another AS path as the one selected
          and announced by BGP. A way to bypass this restriction is to specify
          the AS-path in the PCE Request IRO. In all other cases, the PCE will
          not be sufficiently aware of the route diversity and can not
          select the optimal AS path when computing an inter-domain LSP. To
          avoid this and allow PCE to know route diversity to reach a given
          remote domain, the inter-domain information must be propagated
          between all PCEs without aggregation or summarization. In summary,
          PCEs need to synchronize part of their Database i.e. the
          inter-domain part. Disregarding the protocol, two different
          solutions emerged to exchange inter-domain information:</t>

          <t><list style="symbols">
              <t>Direct Distribution: Exchange TE information using BGP is
              part of this case. In this scenario, it is necessary to
              establish a BGP session between the different domains (whatever
              the platform used, a dedicated router, a PCE, another server
              ...). In the hierarchal PCE scenario, operators that provide
              child PCE, agree to establish a relation with remote domain
              that provides the parent PCE. But, in BRPC, or in Hierarchical
              PCE where almost operators provide a parent PCE, BGP session
              must be establish between networks that have not necessary
              direct adjacency. However, operators should not agree to accept
              relation from other's not directly attached to their network. In
              addition, this scenario could conduct to establish a full mesh
              of BGP session between PCE which could lead into some
              scalability problems.</t>

              <t>Flooding Distribution: In this case, the inter-domain
              information are flood between all PCE so that each PCE is aware
              about all remote domain capabilities. This meets the
              requirement but doesn't provide the flexibility of BGP in term
              of filtering. Indeed, BGP allows through configuration to decide
              which information are announced and to whom. As a per session
              relation, a given operator is not oblige to announce the same
              capabilities to its remote domain. With flooding distribution,
              where everybody redistribute what it has learned without modify
              it, it is not possible to specialize announcement based on
              remote domain.</t>
            </list>So, the solution must provide the possibility to filter
          what is announce per remote domain without authorized the
          summarization or aggregation while keeping a distributed relation
          between domains. In addition, a domain is responsible about the
          Grey-Box announcement and the advertisement information must not be
          modified by intermediate PCE.</t>
        </section>
      </section>

      <section title="TE-LSPs">
        <t>Up to know, the PCE could learn the tunnel already enforce in the
        controlled domain through dedicated NMS system. Recent works on state
        full extensions for PCEP propose to add new messages in order to
        collect information on TE-LSPs from the PCCs.</t>
      </section>

      <section title="Complementary information">
        <t>Most of the time, static information, including PCE Policy, are
        provided through the management system of the operator or by means of
        static configuration (e.g. command line option, configuration file
        ...), but some could be automatically discovered. In particular, in
        intra-domain, PCCs and PCEs can discover automatically reachable PCEs
        (as well as computation domains) through the deployment of <xref
        target="RFC5088">RFC 5088</xref>, for OSPF-controlled networks, and
        <xref target="RFC5089">RFC 5089</xref> for IS-IS controlled networks.
        However, for the inter-PCE discovery at the inter-AS level, no
        mechanism has been standardized (unless ASes are owned by the same
        ISP).</t>
      </section>

      <section title="Operationnal and synchronisation constraints">
        <t>Even if acquired TE information is solved, it remains two major
        problems from an operational point of view.</t>

        <t>First of all, the PCE-DB MUST be synchronised with the underlying
        network topology. This synchronisation is not only mandatory for the
        efficiency of the answer of the PCE, but more to handle the graceful
        restart step of the PCE as well as crash situation. Indeed, for divert
        reasons (maintenance, scheduled operation, failure ...), when the PCE
        start or restart, it MUST acquired the information of the PCE-DB and
        then maintain it synchronised to the underlying network. For the
        stateful version of the PCE, this synchronisation is mandatory as
        TE-LSP tunnel could be setup manually or by the management plane
        independently from the PCE. But, the PCE MUST be aware of them as well
        as when the PCE restart is MUST be aware of TE-LSP it previously
        setup.</t>

        <t>The second point come from the distributed nature of the TED
        information located in the underlying network. Indeed, TE information
        are not located in one place, but distributed amongst all the router
        of the network. Each router manage its links, and, consequently, the
        TE information attached to these links. Thus, modifying a TE
        information on large scale network could become quickly a nightmare
        for operational without any tools to help them. For that purpose, a TE
        Netconf model like proposed in <xref
        target="I-D.clemm-netmod-yang-network-topo">"A YANG Data Model for
        Network Topologies"</xref> is mandatory from an operation point of
        view to allow automatic tools easily configure the TE parameters of a
        network on the routers.</t>
      </section>
    </section>

    <section anchor="IANA" title="IANA Considerations">
      <t>This document makes no request of IANA for the moment.</t>

      <t>Note to RFC Editor: this section may be removed on publication as an
      RFC.</t>
    </section>

    <section anchor="Security" title="Security Considerations">
      <t>Acquisition of information for the PCE TED is of course sensible from
      a security point of view, especially when acquiring information from
      others AS. This section aims at providing best practices to prevent some
      security threat when the PCE try to acquire TED information.</t>

      <section title="Intra-domain information">
        <t>Same security considerations must be applied to the PCE when it is
        connected to an IGP-TE protocol as the routing protocol itself. Best
        practices observed and deployed by operators must also be taken into
        account when installing some PCEs. Indeed, even when deployed as a
        standalone server, PCEs must be considered as a typical router from
        the IGP-TE perspective. As a result, beyond OSPF or IS-IS themselves,
        the usual security rules must be applied, e.g. login/passwd,
        authentication/digest... to protect the connectivity.</t>
      </section>

      <section title="Inter-domain information">
        <t>Inter-domain relation and so information exchange are subject to
        high potential hijack and so need attention from the security point of
        view. To avoid disclosing or expose confidential information that two
        operators would exchange to fill in the TEDs of their respective PCEs,
        the relation SHOULD be protected by standard cryptography mechanism.
        E.g. using IPsec tunnel is RECOMMENDED to protect the connectivity
        between PCEs and the TED exchanges.</t>
      </section>

      <section title="Operational information">
        <t>All operational information like PCE peer addresses are generally
        added manually to the TED and so do not need any particular protection
        nor subject to security. But, as this basic information is needed to
        connected the PCEs to their peers, it could potentially be associated
        to sensitive parameters like login and password. So, standard Best
        Practices are RECOMMENDED to avoid basic security exposition.</t>
      </section>
    </section>

    <section anchor="Acknowledgements" title="Acknowledgements">
      <t>The authors want to thanks PCE's WG members and in particular Daniel
      King for their inputs of this subject.</t>
    </section>
  </middle>

  <back>
    <references title="Normative References">
      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.2119.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.4655.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5440.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5441.xml"?>
    </references>

    <references title="Informative References">
      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5392.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5316.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5088.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5089.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.3630.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.4203.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5305.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5307.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5557.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.6805.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml3/reference.I-D.draft-ietf-pce-stateful-pce-08.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml3/reference.I-D.draft-ietf-ospf-te-metric-extensions-05.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml3/reference.I-D.draft-ietf-idr-ls-distribution-04.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml3/reference.I-D.draft-farrel-interconnected-te-info-exchange-02.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml3/reference.I-D.draft-clemm-netmod-yang-network-topo-01.xml"?>
    </references>
  </back>
</rfc>