<?xml version="1.0" encoding="US-ASCII"?>
<!DOCTYPE rfc SYSTEM "rfc2629.dtd">
<rfc submissionType="IETF" category="bcp" consensus="yes" number="8084" seriesNo="208"
     ipr="trust200902">


  <?rfc toc="yes"?>
  <?rfc symrefs="yes"?>
  <?rfc sortrefs="yes" ?>
  <?rfc compact="yes" ?>
  <?rfc subcompact="no" ?>

  <front>
    <title abbrev="">Network Transport Circuit Breakers</title>

    <author fullname="Godred Fairhurst" initials="G." surname="Fairhurst">
      <organization>University of Aberdeen</organization>

      <address>
        <postal>
          <street>School of Engineering</street>

          <street>Fraser Noble Building</street>

          <city>Aberdeen</city>

          <region>Scotland</region>

          <code>AB24 3UE</code>

          <country>United Kingdom</country>
        </postal>

        <email>gorry@erg.abdn.ac.uk</email>

        <uri>http://www.erg.abdn.ac.uk</uri>
      </address>
    </author>

    <date month="March" year="2017" />

    <area>Transport</area>

     <workgroup>TSVWG Working Group</workgroup>

    <abstract>
      <t>This document explains what is meant by the term "network transport
      Circuit Breaker". It describes the need for Circuit Breakers (CBs) for
      network tunnels and applications when using non-congestion-controlled
      traffic and explains where CBs are, and are not, needed.
      It also defines requirements for building a CB and the
      expected outcomes of using a CB within the Internet.</t>
    </abstract>
  </front>

  <middle>
    <!-- text starts here -->



    <section title="Introduction" toc="include">
      <t>The term "Circuit Breaker" originates in electricity supply, and has
      nothing to do with network circuits or virtual circuits. In electricity
      supply, a Circuit Breaker (CB) is intended as a protection mechanism of last
      resort. Under normal circumstances, a CB ought not to be
      triggered; it is designed to protect the supply network and attached
      equipment when there is overload. People do not expect an electrical
      CB (or fuse) in their home to be triggered, except when
      there is a wiring fault or a problem with an electrical appliance.</t>

      <t>In networking, the CB principle can be used as a
      protection mechanism of last resort to avoid persistent excessive
      congestion impacting other flows that share network capacity. Persistent
      congestion was a feature of the early Internet of the 1980s. This
      resulted in excess traffic starving other connections from access to the
      Internet. It was countered by the requirement to use congestion control
      (CC) in the Transmission Control Protocol (TCP) <xref
      target="Jacobson88"></xref>. These mechanisms operate in Internet hosts
      to cause TCP connections to "back off" during congestion. The addition
      of a congestion control to TCP (currently documented in <xref
      target="RFC5681"></xref>) ensured the stability of the Internet, because
      it was able to detect congestion and promptly react. This was effective
      in an Internet where most TCP flows were long lived (ensuring that they
      could detect and respond to congestion before the flows terminated).
      Although TCP was, by far, the dominant traffic, this is no longer the
      always the case, and non-congestion-controlled traffic, including many
      applications using the User Datagram Protocol (UDP), can form a
      significant proportion of the total traffic traversing a link.  To avoid persistent excessive congestion, the current Internet therefore requires consideration of the way that non-congestion-controlled traffic is forwarded.</t>

      <t>A network transport CB is an automatic mechanism that is
      used to continuously monitor a flow or aggregate set of flows. The
      mechanism seeks to detect when the flow(s) experience persistent
      excessive congestion. When this is detected, a CB
      terminates (or significantly reduces the rate of) the flow(s). This is a
      safety measure to prevent starvation of network resources denying other
      flows from access to the Internet. Such measures are essential for an
      Internet that is heterogeneous and for traffic that is hard to predict
      in advance. Avoiding persistent excessive congestion is important to
      reduce the potential for "Congestion Collapse" <xref
      target="RFC2914"></xref>.</t>

      <t>There are important differences between a transport CB
      and a congestion control method. Congestion control (as implemented in
      TCP, Stream Control Transmission Protocol (SCTP), and Datagram Congestion Control Protocol (DCCP)) operates on a timescale on the order of a packet
      Round-Trip Time (RTT): the time from sender to destination and return.
      Congestion at a network link can also be detected using Explicit
      Congestion Notification (ECN) <xref target="RFC3168"></xref>, which
      allows the network to signal congestion by marking ECN-capable packets
      with a Congestion Experienced (CE) mark. Both loss and reception of
      CE-marked packets are treated as congestion events. Congestion control
      methods are able to react to a congestion event by continuously adapting
      to reduce their transmission rate. The goal is usually to limit the
      transmission rate to a maximum rate that reflects a fair use of the
      available capacity across a network path. These methods typically
      operate on individual traffic flows (e.g., a 5-tuple that includes the
      IP addresses, protocol, and ports).</t>

      <t>In contrast, CBs are recommended for
      non-congestion-controlled Internet flows and for traffic aggregates,
      e.g., traffic sent using a network tunnel. They operate on timescales
      much longer than the packet RTT, and trigger under situations of
      abnormal (excessive) congestion. People have been implementing what this
      document characterizes as CBs on an ad hoc basis to protect
      Internet traffic. This document therefore provides guidance on how to
      deploy and use these mechanisms. Later sections provide examples of
      cases where CBs may or may not be desirable.</t>

      <t>A CB needs to measure (meter) some portion of the
      traffic to determine if the network is experiencing congestion and needs
      to be designed to trigger robustly when there is persistent excessive
      congestion.</t>

      <t>A CB trigger will often utilize a series of successive
      sample measurements metered at an ingress point and an egress point
      (either of which could be a transport endpoint). The trigger needs to
      operate on a timescale much longer than the path RTT (e.g.,
      seconds to possibly many tens of seconds). This longer period is needed
      to provide sufficient time for transport congestion control or
      applications to adjust their rate following congestion, and for the
      network load to stabilize after any adjustment. Congestion events can be
      common when a congestion-controlled transport is used over a network
      link operating near capacity. Each event results in reduction in the
      rate of the transport flow experiencing congestion. The longer period
      seeks to ensure that a CB is not accidentally triggered
      following a single (or even successive) congestion event(s).</t>

      <t>Once triggered, the CB needs to provide a control
      function (called the "reaction"). This removes traffic from the network,
      either by disabling the flow or by significantly reducing the level of
      traffic. This reaction provides the required protection to prevent
      persistent excessive congestion being experienced by other flows that
      share the congested part of the network path.</t>

      <t><xref target="Require"></xref> defines requirements for building a
      CB.</t>

      <t>The operational conditions that cause a CB to trigger
      ought to be regarded as abnormal. Examples of situations that could
      trigger a CB include:<list style="symbols">
          <t>anomalous traffic that exceeds the provisioned capacity (or whose
          traffic characteristics exceed the threshold configured for the
          CB);</t>

          <t>traffic generated by an application at a time when the
          provisioned network capacity is being utilized for other
          purposes;</t>

          <t>routing changes that cause additional traffic to start using the
          path monitored by the CB;</t>

          <t>misconfiguration of a service/network device where the capacity
          available is insufficient to support the current traffic
          aggregate;</t>

          <t>misconfiguration of an admission controller or traffic policer
          that allows more traffic than expected across the path monitored by
          the CB.</t>
        </list></t>

      <t>Other mechanisms could also be available to network operators to
      detect excessive congestion (e.g., an observation of excessive
      utilization for a port on a network device). Utilizing such information,
      operational mechanisms could react to reduce network load over a shorter
      timescale than those of a network transport CB. The role of
      the CB over such paths remains as a method of last resort.
      Because it acts over a longer timescale, the CB ought to
      be triggered only when other reactions did not succeed in reducing persistent
      excessive congestion.</t>

      <t>In many cases, the reason for triggering a CB will not
      be evident to the source of the traffic (user, application, endpoint,
      etc.). A CB can be used to limit traffic from applications
      that are unable, or choose not, to use congestion control or in cases in which the
      congestion control properties of the traffic cannot be relied upon
      (e.g., traffic carried over a network tunnel). In such circumstances, it
      is all but impossible for the CB to signal back to the
      impacted applications. In some cases, applications could therefore have
      difficulty in determining that a CB has been triggered and
      where in the network this happened.</t>

      <t>Application developers are therefore advised, where possible, to
      deploy appropriate congestion control mechanisms. An application that
      uses congestion control will be aware of congestion events in the
      network. This allows it to regulate the network load under congestion,
      and it is expected to avoid triggering a network CB. For
      applications that can generate elastic traffic, this will often be a
      preferred solution.</t>

      <section title="Types of CBs">
        <t>There are various forms of network transport CBs. These
        are differentiated mainly on the timescale over which they are
        triggered, but also in the intended protection they offer:<list
            style="symbols">
            <t>Fast-Trip CBs: The relatively short timescale used
            by this form of CB is intended to provide protection
            for network traffic from a single flow or related group of
            flows.</t>

            <t>Slow-Trip CBs: This CB utilizes a
            longer timescale and is designed to protect network traffic from
            congestion by traffic aggregates.</t>

            <t>Managed CBs: Utilize the operations and management
            functions that might be present in a managed service to implement
            a CB.</t>
          </list>Examples of each type of CB are provided in
        <xref target="Require"/>.</t>
      </section>
    </section>

    <section title="Terminology" toc="include">
      <t>The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
      "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
      document are to be interpreted as described in <xref
      target="RFC2119"></xref>.</t>
    </section>

    <section title="Design of a CB (What makes a good CB?)"
             toc="include">
      <t>Although CBs have been talked about in the IETF for many
      years, there has not yet been guidance on the cases where CBs
      are needed or upon the design of CB mechanisms.
      This document seeks to offer advice on these two topics.</t>

      <t>CBs are RECOMMENDED for IETF protocols and tunnels that
      carry non-congestion-controlled Internet flows and for traffic
      aggregates. This includes traffic sent using a network tunnel. Designers
      of other protocols and tunnel encapsulations also ought to consider the
      use of these techniques as a last resort to protect traffic that shares
      the network path being used.</t>

      <t>This document defines the requirements for the design of a CB
      and provides examples of how a CB can be
      constructed. The specifications of individual protocols and tunnel
      encapsulations need to detail the protocol mechanisms needed to
      implement a CB.</t>

      <t><xref target="function" /> describes the functional components of a CB
      and <xref target="other" /> defines requirements for implementing a CB.</t>

      <section title="Functional Components" toc="include" anchor="function">
        <t>The basic design of a CB involves communication
        between an ingress point (a sender) and an egress point (a receiver)
        of a network flow or set of flows. A simple picture of operation is
        provided in Figure 1. This shows a set of routers (each labeled R)
        connecting a set of endpoints.</t>

        <t>A CB is used to control traffic passing through a
        subset of these routers, acting between the ingress and a egress point
        network devices. The path between the ingress and egress could be
        provided by a tunnel or other network-layer technique. One expected
        use would be at the ingress and egress of a service, where all traffic
        being considered terminates beyond the egress point; hence, the
        ingress and egress carry the same set of flows.</t>

        <figure>
          <artwork><![CDATA[
 +--------+                                                   +--------+
 |Endpoint|                                                   |Endpoint|
 +--+-----+          >>> circuit breaker traffic >>>          +--+-----+
    |                                                            |
    | +-+  +-+  +---------+  +-+  +-+  +-+  +--------+  +-+  +-+ |
    +-+R+--+R+->+ Ingress +--+R+--+R+--+R+--+ Egress |--+R+--+R+-+
      +++  +-+  +------+--+  +-+  +-+  +-+  +-----+--+  +++  +-+
       |         ^     |                          |      |
       |         |  +--+------+            +------+--+   |
       |         |  | Ingress |            | Egress  |   |
       |         |  | Meter   |            | Meter   |   |
       |         |  +----+----+            +----+----+   |
       |         |       |                      |        |
  +-+  |         |  +----+----+                 |        |  +-+
  |R+--+         |  | Measure +<----------------+        +--+R|
  +++            |  +----+----+      Reported               +++
   |             |       |           Egress                  |
   |             |  +----+----+      Measurement             |
+--+-----+       |  | Trigger +                           +--+-----+
|Endpoint|       |  +----+----+                           |Endpoint|
+--------+       |       |                                +--------+
                 +---<---+
                  Reaction

]]></artwork>
        </figure>

        <t>Figure 1: A CB controlling the part of the end-to-end path between
        an ingress point and an egress point. Note in some cases, the
        trigger and measurement functions could alternatively be located at
        other locations (e.g., at a network operations center).</t>

        <t>In the context of a CB, the ingress and egress
        functions could be implemented in different places. For example, they
        could be located in network devices at a tunnel ingress and at the
        tunnel egress. In some cases, they could be located at one or both
        network endpoints (see Figure 2), implemented as components within a
        transport protocol.</t>

        <t><figure>
            <artwork><![CDATA[
 +----------+                 +----------+
 | Ingress  |  +-+  +-+  +-+  | Egress   |
 | Endpoint +->+R+--+R+--+R+--+ Endpoint |
 +--+----+--+  +-+  +-+  +-+  +----+-----+
    ^    |                         |
    | +--+------+             +----+----+  
    | | Ingress |             | Egress  |
    | | Meter   |             | Meter   |
    | +----+----+             +----+----+
    |      |                       |
    | +--- +----+                  | 
    | | Measure +<-----------------+
    | +----+----+      Reported                      
    |      |           Egress            
    | +----+----+      Measurement         
    | | Trigger |    
    | +----+----+     
    |      |                      
    +---<--+
    Reaction

]]></artwork>
          </figure></t>

        <t>Figure 2: An endpoint CB implemented at the sender (ingress) and
        receiver (egress).</t>

        <t>The set of components needed to implement a CB
        are:</t>

        <t><list style="numbers">
            <t>An ingress meter (at the sender or tunnel ingress) that records
            the number of packets/bytes sent in each measurement interval.
            This measures the offered network load for a flow or set of flows.
            For example, the measurement interval could be many seconds (or
            every few tens of seconds or a series of successive shorter
            measurements that are combined by the CB Measurement
            function).</t>

            <t>An egress meter (at the receiver or tunnel egress) that records
            the number/bytes received in each measurement interval. This
            measures the supported load for the flow or set of flows, and
            it could utilize other signals to detect the effect of congestion
            (e.g., loss/congestion marking <xref target="RFC3168"></xref>
            experienced over the path). The measurements at the egress could
            be synchronized (including an offset for the time of flight of the
            data, or referencing the measurements to a particular packet) to
            ensure any counters refer to the same span of packets.</t>

            <t>A method that communicates the measured values at the ingress
            and egress to the CB Measurement function. This could
            use several methods including sending return measurement packets
            (or control messages) from a receiver to a trigger function at the
            sender; an implementation using Operations, Administration and
            Management (OAM); or sending an in-band signaling datagram to the
            trigger function. This could also be implemented purely as a
            control-plane function, e.g., using a software-defined network
            controller.</t>

            <t>A measurement function that combines the ingress and egress
            measurements to assess the present level of network congestion.
            (For example, the loss rate for each measurement interval could be
            deduced from calculating the difference between ingress and egress
            counter values.) Note the method does not require high accuracy
            for the period of the measurement interval (or therefore the
            measured value, since isolated and/or infrequent loss events need
            to be disregarded).</t>

            <t>A trigger function that determines whether the measurements
            indicate persistent excessive congestion. This function defines an
            appropriate threshold for determining that there is persistent
            excessive congestion between the ingress and egress. This
            preferably considers a rate or ratio, rather than an absolute
            value (e.g., more than 10% loss, but other methods could also be
            based on the rate of transmission as well as the loss rate). The
            CB is triggered when the threshold is exceeded in
            multiple measurement intervals (e.g., three successive measurements).
            Designs need to be robust so that single or spurious events do not
            trigger a reaction.</t>

            <t>A reaction that is applied at the ingress when the CB
            is triggered. This seeks to automatically remove the
            traffic causing persistent excessive congestion.</t>

            <t>A feedback control mechanism that triggers when either the
            ingress and egress measurements are not available,
            since this also could indicate a loss of control packets (also a
            symptom of heavy congestion or inability to control the load).</t>
          </list></t>
      </section>

      <section title="Other Network Topologies" anchor="other">
        <t>A CB can be deployed in networks with topologies
        different from that presented in Figures 1 and 2. This section describes
        examples of such usage and possible places where functions can be
        implemented.</t>


        <section title="Use with a Multicast Control/Routing Protocol">
          <t><figure >
              <artwork><![CDATA[
 +----------+                 +--------+  +----------+                       
 | Ingress  |  +-+  +-+  +-+  | Egress |  |  Egress  |
 | Endpoint +->+R+--+R+--+R+--+ Router |--+ Endpoint +->+
 +----+-----+  +-+  +-+  +-+  +---+--+-+  +----+-----+  |
      ^         ^    ^    ^       |  ^         |        |  
      |         |    |    |       |  |         |        | 
 +----+----+    + - - - < - - - - +  |    +----+----+   | Reported
 | Ingress |      multicast Prune    |    | Egress  |   | Ingress
 | Meter   |                         |    | Meter   |   | Measurement
 +---------+                         |    +----+----+   | 
                                     |         |        |
                                     |    +----+----+   |
                                     |    | Measure +<--+ 
                                     |    +----+----+ 
                                     |         | 
                                     |    +----+----+ 
                           multicast |    | Trigger |  
                           Leave     |    +----+----+ 
                           Message   |         | 
                                     +----<----+

]]></artwork>
            </figure>Figure 3: An example of a multicast CB controlling the
          end-to-end path between an ingress endpoint and an egress
          endpoint.</t>

          <t>Figure 3 shows one example of how a multicast CB
          could be implemented at a pair of multicast endpoints (e.g., to
          implement a Fast-Trip CB, <xref target="FCB"></xref>).
          The ingress endpoint (the sender that sources the multicast traffic)
          meters the ingress load, generating an ingress measurement (e.g.,
          recording timestamped packet counts), and it sends this measurement to
          the multicast group together with the traffic it has measured.</t>

          <t>Routers along a multicast path forward the multicast traffic
          (including the ingress measurement) to all active endpoint
          receivers. Each last hop (egress) router forwards the traffic to one
          or more egress endpoints.</t>

          <t>In Figure 3, each endpoint includes a meter that performs a
          local egress load measurement. An endpoint also extracts the
          received ingress measurement from the traffic and compares the
          ingress and egress measurements to determine if the CB
          ought to be triggered. This measurement has to be robust to loss
          (see the previous section). If the CB is triggered, it
          generates a multicast leave message for the egress (e.g., an IGMP or
          MLD message sent to the last-hop router), which causes the upstream
          router to cease forwarding traffic to the egress endpoint <xref
          target="RFC1112"></xref>.</t>

          <t>Any multicast router that has no active receivers for a
          particular multicast group will prune traffic for that group,
          sending a prune message to its upstream router. This starts the
          process of releasing the capacity used by the traffic and is a
          standard multicast routing function (e.g., using Protocol
          Independent Multicast - Sparse Mode (PIM-SM) routing protocol <xref
          target="RFC4601"></xref>). Each egress operates autonomously, and
          the CB "reaction" is executed by the multicast control
          plane (e.g., by PIM) requiring no explicit signaling by the CB
          along the communication path used for the control messages.
          Note there is no direct communication with the ingress; hence, a
          triggered CB only controls traffic downstream of the
          first-hop multicast router. It does not stop traffic flowing from
          the sender to the first-hop router; this is common practice for
          multicast deployment.</t>

          <t>The method could also be used with a multicast tunnel or
          subnetwork (e.g., <xref target="SCB"></xref>, <xref
          target="MCB"></xref>), where a meter at the ingress generates
          additional control messages to carry the measurement data towards
          the egress where the egress metering is implemented.</t>
        </section>

        <section title="Use with Control Protocols Supporting Pre-provisioned Capacity">
          <t>Some paths are provisioned using a control protocol, e.g., flows
          provisioned using the Multiprotocol Label Switching (MPLS)
          services, paths provisioned using the Resource Reservation Protocol
          (RSVP), networks utilizing Software-Defined Network (SDN) functions,
          or admission-controlled Differentiated Services. Figure 1 shows one
          expected use case, where in this usage a separate device could be
          used to perform the measurement and trigger functions. The reaction
          generated by the trigger could take the form of a network-control
          message sent to the ingress and/or other network elements causing
          these elements to react to the CB. Examples of this
          type of use are provided in <xref target="MCB"></xref>.</t>
        </section>

        <section anchor="unidir"
                 title="Unidirectional CBs over Controlled Paths">
          <t>A CB can be used to control unidirectional UDP
          traffic, providing that there is a communication path that can be
          used for control messages to connect the functional components at
          the ingress and egress. This communication path for the control
          messages can exist in networks for which the traffic flow is purely
          unidirectional. For example, a multicast stream that sends packets
          across an Internet path and can use multicast routing to prune flows
          to shed network load. Some other types of subnetwork also utilize
          control protocols that can be used to control traffic flows.</t>
        </section>
      </section>
    </section>

    <section anchor="Require"
             title="Requirements for a Network Transport CB">
      <t>The requirements for implementing a CB are:</t>

      <t><!--The order of requirments was updated in -01.

--></t>

      <t><list style="numbers">
          <t>There needs to be a communication path for control messages to
          carry measurement data from the ingress meter and from the egress
          meter to the point of measurement. (Requirements 16-18 relate to the
          transmission of control messages.)</t>

          <t>A CB is REQUIRED to define a measurement period over which the CB
          Measurement function measures the level of congestion or loss. This
          method does not have to detect individual packet loss, but it MUST have
          a way to know that packets have been lost/marked from the traffic
          flow.</t>


          <t>An egress meter can also count ECN <xref target="RFC3168"></xref>
          Congestion Experienced (CE) marks as a part of measurement of congestion, but in this
          case, loss MUST also be measured to provide a complete view of the
          level of congestion. For tunnels, <xref
          target="CONGESTION-FEEDBACK"></xref> describes
          a way to measure both loss and ECN-marking; these measurements could
          be used on a relatively short timescale to drive a congestion control response and/or aggregated over a longer timescale with a
          higher trigger threshold to drive a CB. Subsequent bullet items in
          this section discuss the necessity of using a longer timescale and a
          higher trigger threshold.</t>

          <t>The measurement period used by a CB Measurement function MUST be
          longer than the time that current Congestion Control algorithms need
          to reduce their rate following detection of congestion. This is
          important because end-to-end Congestion Control algorithms require
          at least one RTT to notify and adjust the traffic when congestion is
          experienced, and congestion bottlenecks can share traffic with a
          diverse range of end-to-end RTTs. The measurement period is therefore expected
          to be significantly longer than the RTT experienced by the CB
          itself.</t>

          <t>If necessary, a CB MAY combine successive individual meter
          samples from the ingress and egress to ensure observation of an
          average measurement over a sufficiently long interval. (Note when
          meter samples need to be combined, the combination needs to reflect
          the sum of the individual sample counts divided by the total
          time/volume over which the samples were measured. Individual samples
          over different intervals cannot be directly combined to generate an
          average value.)</t>

          <t>A CB MUST be constructed so that it does not trigger under light
          or intermittent congestion (see requirements 7-9).</t>

          <t>A CB is REQUIRED to define a threshold to determine whether the
          measured congestion is considered excessive.</t>

          <t>A CB is REQUIRED to define the triggering interval, defining the
          period over which the trigger uses the collected measurements. CBs
          need to trigger over a sufficiently long period to avoid
          additionally penalizing flows with a long path RTT (e.g., many path
          RTTs).</t>

          <t>A CB MUST be robust to multiple congestion events. This usually
          will define a number of measured persistent congestion events per
          triggering period. For example, a CB MAY combine the results of
          several measurement periods to determine if the CB is triggered
          (e.g., it is triggered when persistent excessive congestion is
          detected in three of the measurements within the triggering
          interval when more than three measurements were collected).</t>

          <t>The normal reaction to a trigger SHOULD disable all traffic that
          contributed to congestion (otherwise, see requirements 11 and 12).</t>

          <t>The reaction MUST be much more severe than that of a Congestion
          Control algorithm (such as TCP's congestion control <xref
          target="RFC5681"></xref> or TCP-Friendly Rate Control, TFRC <xref
          target="RFC5348"></xref>), because the CB reacts to more persistent
          congestion and operates over longer timescales (i.e., the overload
          condition will have persisted for a longer time before the CB is
          triggered).</t>

          <t>A reaction that results in a reduction SHOULD result in reducing
          the traffic by at least an order of magnitude. A response that
          achieves the reduction by terminating flows, rather than randomly
          dropping packets, will often be more desirable to users of the
          service. A CB that reduces the rate of a flow, MUST continue to
          monitor the level of congestion and MUST further react to reduce the
          rate if the CB is again triggered.</t>

          <t>The reaction to a triggered CB MUST continue for a period that is
          at least the triggering interval. Operator intervention will usually
          be required to restore a flow. If an automated response is needed to
          reset the trigger, then this needs to not be immediate. The design
          of an automated reset mechanism needs to be sufficiently
          conservative that it does not adversely interact with other
          mechanisms (including other CB algorithms that control traffic over
          a common path). It SHOULD NOT perform an automated reset when there
          is evidence of continued congestion.</t>

          <t>A CB trigger SHOULD be regarded as an abnormal network event. As
          such, this event SHOULD be logged. The measurements that lead to
          triggering of the CB SHOULD also be logged.</t>

          <t>The control communication needs to carry measurements
          (requirement 1) and, in some uses, also needs to transmit trigger
          messages to the ingress. This control communication may be in or out of band.
          The use of in-band communication is RECOMMENDED when
          either design would be possible. The preferred CB design is one that
          triggers when it fails to receive measurement reports that indicate
          an absence of congestion, in contrast to relying on the successful
          transmission of a "congested" signal back to the sender. (The
          feedback signal could itself be lost under congestion).<list
              style="hanging">
              <t hangText="In Band:">An in-band control method SHOULD assume
              that loss of control messages is an indication of potential
              congestion on the path, and repeated loss ought to cause the CB
              to be triggered. This design has the advantage that it provides
              fate-sharing of the traffic flow(s) and the control
              communications. This fate-sharing property is weaker when some
              or all of the measured traffic is sent using a path that differs
              from the path taken by the control traffic (e.g., where traffic
              and control messages follow a different path due to use of
              equal-cost multipath routing, traffic engineering, or tunnels
              for specific types of traffic).</t>

              <t hangText="Out of Band:">An out-of-band control method SHOULD
              NOT trigger a CB reaction when there is loss of control messages
              (e.g., a loss of measurements). This avoids failure
              amplification/propagation when the measurement and data paths
              fail independently. A failure of an out-of-band communication
              path SHOULD be regarded as an abnormal network event and be handled
              as appropriate for the network; for example, this event SHOULD be
              logged, and additional network operator action might be
              appropriate, depending on the network and the traffic
              involved.</t>
            </list></t>

          <t>The control communication MUST be designed to be robust to packet
          loss. A control message can be lost if there is a failure of the
          communication path used for the control messages, loss is likely also to
          be experienced during congestion/overload. This does not imply
          that it is desirable to provide reliable delivery (e.g., over TCP),
          since this can incur additional delay in responding to congestion.
          Appropriate mechanisms could be to duplicate control messages to
          provide increased robustness to loss and/or to regard a lack of
          control traffic as an indication that excessive congestion could be
          being experienced <xref target="RFC8085"></xref>.
          If control message traffic is sent over a shared path, it is
          RECOMMENDED that this control traffic is prioritized to reduce the
          probability of loss under congestion. Control traffic also needs to
          be considered when provisioning a network that uses a CB.</t>

          <t>There are security requirements for the control communication
          between endpoints and/or network devices (<xref
          target="sec"></xref>). The authenticity of the source and integrity
          of the control messages (measurements and triggers) MUST be
          protected from off-path attacks. When there is a risk of an on-path
          attack, a cryptographic authentication mechanism for all
          control/measurement messages is RECOMMENDED.</t>
        </list></t>
    </section>

    <section title="Examples of CBs">
      <t>There are multiple types of CB that could be defined for
      use in different deployment cases. There could be cases where a flow
      becomes controlled by multiple CBs (e.g., when the traffic
      of an end-to-end flow is carried in a tunnel within the network). This
      section provides examples of different types of CB.</t>

      <section anchor="FCB" title="A Fast-Trip CB">
        <t><xref target="RFC2309"></xref> discusses the dangers of
        congestion unresponsive flows and states that "all UDP-based streaming
        applications should incorporate effective congestion avoidance
        mechanisms."  Some applications do not use a full-featured transport
        (TCP, SCTP, DCCP). These applications (e.g., using UDP and its
        UDP-Lite variant) need to provide appropriate congestion avoidance.
        Guidance for applications that do not use congestion-controlled
        transports is provided in <xref
        target="RFC8085"></xref>. Such mechanisms can be
        designed to react on much shorter timescales than a CB,
        that only observes a traffic envelope. Congestion control methods can
        also interact with an application to more effectively control its
        sending rate.</t>

        <t>A Fast-trip CB is the most responsive form of CB.  It has a response time that is only slightly larger than that
        of the traffic that it controls. It is suited to traffic with
        well-understood characteristics (and could include one or more trigger
        functions specifically tailored the type of traffic for which it is
        designed). It is not suited to arbitrary network traffic and could be
        unsuitable for traffic aggregates, since it could prematurely trigger
        (e.g., when the combined traffic from multiple congestion-controlled
        flows leads to short-term overload).</t>

        <t>Although the mechanisms can be implemented in RTP-aware network
        devices, these mechanisms are also suitable for implementation in
        endpoints (e.g., as a part of the transport system) where they can
        also complement end-to-end congestion control methods. A shorter
        response time enables these mechanisms to triggers before other forms
        of CB (e.g., CBs operating on traffic
        aggregates at a point along the network path).</t>

        <section title="A Fast-Trip CB for RTP">
          <t>A set of Fast-Trip CB methods have been specified
          for use together by a Real-time Transport Protocol (RTP) flow using
          the RTP/AVP Profile <xref target="RFC8083"></xref>. It is expected
          that, in the absence of severe congestion, all RTP applications
          running on best-effort IP networks will be able to run without
          triggering these CBs. An RTP Fast-Trip CB
          is therefore implemented as a fail-safe that, when triggered, will
          terminate RTP traffic.</t>

          <t>The sending endpoint monitors reception of in-band RTP Control
          Protocol (RTCP) reception report blocks, as contained in sender report (SR) or receiver report (RR)
          packets, that convey reception quality feedback information. This is
          used to measure (congestion) loss, possibly in combination with ECN
          <xref target="RFC6679"></xref>.</t>

          <t>The CB action (shutdown of the flow) triggers
          when any of the following trigger conditions are true:</t>

          <t><list style="numbers">
              <t>An RTP CB triggers on reported lack of
              progress.</t>

              <t>An RTP CB triggers when no receiver reports
              messages are received.</t>

              <t>An RTP CB triggers when the long-term RTP
              throughput (over many RTTs) exceeds a hard upper limit
              determined by a method that resembles TCP-Friendly Rate Control
              (TFRC).</t>

              <t>An RTP CB includes the notion of Media
              Usability. This CB is triggered when the quality of
              the transported media falls below some required minimum
              acceptable quality.</t>
            </list></t>
        </section>
      </section>

      <section anchor="SCB" title="A Slow-Trip CB">
        <t>A Slow-Trip CB could be implemented in an endpoint or
        network device. This type of CB is much slower at
        responding to congestion than a Fast-Trip CB. This is
        expected to be more common.</t>

        <t>One example where a Slow-Trip CB is needed is where
        flows or traffic-aggregates use a tunnel or encapsulation and the
        flows within the tunnel do not all support TCP-style congestion
        control (e.g., TCP, SCTP, TFRC), see <xref
        target="RFC8085"></xref>, Section 3.1.3. A use case
        is where tunnels are deployed in the general Internet (rather than
        "controlled environments" within an Internet service provider or
        enterprise network), especially when the tunnel could need to cross a
        customer access router.</t>
      </section>

      <section anchor="MCB" title="A Managed CB">
        <t>A managed CB is implemented in the signaling protocol
        or management plane that relates to the traffic aggregate being
        controlled. This type of CB is typically applicable when
        the deployment is within a "controlled environment".</t>

        <t>A CB requires more than the ability to determine that
        a network path is forwarding data or to measure the rate of a path --
        which are often normal network operational functions. There is an
        additional need to determine a metric for congestion on the path and
        to trigger a reaction when a threshold is crossed that indicates
        persistent excessive congestion.</t>

        <t>The control messages can use either in-band or out-of-band
        communications.</t>

        <section title="A Managed CB for SAToP Pseudowires">
          <t>Section 8 of <xref target="RFC4553"></xref>, SAToP Pseudowire Emulation Edge-to-Edge (PWE3),
          describes an example of a managed CB for
          isochronous flows.</t>

          <t>If such flows were to run over a pre-provisioned (e.g.,
          Multiprotocol Label Switching, MPLS) infrastructure, then it could
          be expected that the PW would not experience
          congestion, because a flow is not expected to either increase (or
          decrease) their rate. If, instead, PW traffic is multiplexed with
          other traffic over the general Internet, it could experience
          congestion. <xref target="RFC4553"></xref> states: "If SAToP PWs run
          over a PSN providing best-effort service, they SHOULD monitor packet
          loss in order to detect 'severe congestion'." The currently
          recommended measurement period is 1 second, and the trigger operates
          when there are more than three measured Severely Errored Seconds
          (SES) within a period. <xref target="RFC4553"></xref> goes on to state that "If such a condition is detected, a SAToP PW
          ought to shut down bi-directionally for some period of time...".</t>

          <t>The concept was that when the packet-loss ratio (congestion)
          level increased above a threshold, the PW was, by default, disabled.
          This use case considered fixed-rate transmission, where the PW had
          no reasonable way to shed load.</t>

          <t>The trigger needs to be set at a rate at which the PW is likely to
   experience a serious problem, possibly making the service non-compliant. At this point, triggering the CB would
          remove the traffic preventing undue impact on congestion-responsive
          traffic (e.g., TCP). Part of the rationale was that high-loss
          ratios typically indicated that something was "broken" and ought to
          have already resulted in operator intervention and therefore now need
          to trigger this intervention.</t>

          <t>An operator-based response to the triggering of a CB
          provides an opportunity for other action to restore the service
          quality (e.g., by shedding other loads or assigning additional
          capacity) or to consciously avoid reacting to the trigger while
          engineering a solution to the problem. This could require the
          trigger function to send a control message to a third location
          (e.g., a network operations center, NOC) that is responsible for
          operation of the tunnel ingress, rather than the tunnel ingress
          itself.</t>
        </section>

        <section title="A Managed CB for Pseudowires (PWs)">
          <t>Pseudowires (PWs) <xref target="RFC3985"></xref> have become a
          common mechanism for tunneling traffic, and they could compete for
          network resources both with other PWs and with non-PW traffic, such
          as TCP/IP flows.</t>

          <t><xref target="RFC7893"></xref> discusses congestion
          conditions that can arise when PWs compete with elastic (i.e.,
          congestion responsive) network traffic (e.g., TCP traffic). Elastic
          PWs carrying IP traffic (see <xref target="RFC4448"></xref>) do not
          raise major concerns because all of the traffic involved responds,
          reducing the transmission rate when network congestion is
          detected.</t>

          <t>In contrast, inelastic PWs (e.g., a fixed-bandwidth Time Division
          Multiplex, TDM <xref target="RFC4553"></xref> <xref
          target="RFC5086"></xref> <xref target="RFC5087"></xref>) have the
          potential to harm congestion-responsive traffic or to contribute to
          excessive congestion because inelastic PWs do not adjust their
          transmission rate in response to congestion. <xref
          target="RFC7893"></xref> analyses TDM PWs, with an
          initial conclusion that a TDM PW operating with a degree of loss
          that could result in congestion-related problems is also operating
          with a degree of loss that results in an unacceptable TDM service.
          For that reason, the document suggests that a managed CB
          that shuts down a PW when it persistently fails to deliver
          acceptable TDM service is a useful means for addressing these
          congestion concerns. (See Appendix A of <xref
          target="RFC7893"></xref> for further discussion.)</t>
        </section>
      </section>
    </section>

    <section title="Examples in Which CBs May Not Be Needed">
      <t>A CB is not required for a single congestion-controlled
      flow using TCP, SCTP, TFRC, etc. In these cases, the congestion control
      methods are already designed to prevent persistent excessive
      congestion.</t>

      <section title="CBs over Pre-provisioned Capacity">
        <t>One common question is whether a CB is needed when a
        tunnel is deployed in a private network with pre-provisioned
        capacity.</t>

        <t>In this case, compliant traffic that does not exceed the
        provisioned capacity ought not to result in persistent congestion. A
        CB will hence only be triggered when there is
        non-compliant traffic. It could be argued that this event ought never
        to happen -- but it could also be argued that the CB
        equally ought never to be triggered. If a CB were to be
        implemented, it will provide an appropriate response, if persistent
        congestion occurs in an operational network.</t>

        <t>Implementing a CB will not reduce the performance of
        the flows, but in the event that persistent excessive congestion
        occurs, it protects network traffic that shares network capacity with
        these flows. It also protects network traffic from a failure when
        CB traffic is (re)routed to cause additional network load
        on a non-pre-provisioned path.</t>
      </section>

      <section title="CBs with Tunnels Carrying Congestion-Controlled Traffic">
        <t>IP-based traffic is generally assumed to be congestion controlled,
        i.e., it is assumed that the transport protocols generating IP-based
        traffic at the sender already employ mechanisms that are sufficient to
        address congestion on the path. Therefore, a question arises when
        people deploy a tunnel that is thought to carry only an aggregate of
        TCP traffic (or traffic using some other congestion control method):
        Is there an advantage in this case in using a CB?</t>

        <t>TCP (and SCTP) traffic in a tunnel is expected to reduce the
        transmission rate when network congestion is detected. Other
        transports (e.g., using UDP) can employ mechanisms that are sufficient
        to address congestion on the path <xref
        target="RFC8085"></xref>. However, even if the
        individual flows sharing a tunnel each implement a congestion control
        mechanism, and individually reduce their transmission rate when
        network congestion is detected, the overall traffic resulting from the
        aggregate of the flows does not necessarily avoid persistent
        congestion. For instance, most congestion control mechanisms require
        long-lived flows to react to reduce the rate of a flow. An aggregate
        of many short flows could result in many flows terminating before they
        experience congestion. It is also often impossible for a tunnel
        service provider to know that the tunnel only contains
        congestion-controlled traffic (e.g., Inspecting packet headers might
        not be possible). Some IP-based applications might not implement
        adequate mechanisms to address congestion. The important thing to note
        is that if the aggregate of the traffic does not result in persistent
        excessive congestion (impacting other flows), then the CB
        will not trigger. This is the expected case in this context -- so
        implementing a CB ought not to reduce performance of the
        tunnel, but in the event that persistent excessive congestion occurs,
        the CB protects other network traffic that shares
        capacity with the tunnel traffic.</t>
      </section>

      <section title="CBs with Unidirectional Traffic and No Control Path">
        <t>A one-way forwarding path could have no associated communication
        path for sending control messages; therefore, it cannot be controlled
        using a CB (compare with <xref
        target="unidir"></xref>).</t>

        <t>A one-way service could be provided using a path with dedicated
        pre-provisioned capacity that is not shared with other elastic
        Internet flows (i.e., flows that vary their rate). A forwarding path
        could also be shared with other flows. One way to mitigate the impact
        of traffic on the other flows is to manage the traffic envelope by
        using ingress policing. Supporting this type of traffic in the general
        Internet requires operator monitoring to detect and respond to
        persistent excessive congestion.</t>
      </section>
    </section>

    <section anchor="sec" title="Security Considerations" toc="include">
      <t>All CB mechanisms rely upon coordination between the
      ingress and egress meters and communication with the trigger function.
      This is usually achieved by passing network-control information (or
      protocol messages) across the network. Timely operation of a CB
      depends on the choice of measurement period. If the receiver has
      an interval that is overly long, then the responsiveness of the CB
      decreases. This impacts the ability of the CB to
      detect and react to congestion. If the interval is too short, the CB
      could trigger prematurely resulting in insufficient time for
      other mechanisms to act and potentially resulting in unnecessary disruption
      to the service.</t>

      <t>A CB could potentially be exploited by an attacker to
      mount a Denial-of-Service (DoS) attack against the traffic being
      controlled by the CB. Therefore, mechanisms need to be
      implemented to prevent attacks on the network-control information that
      would result in DoS.</t>

      <t>The authenticity of the source and integrity of the control messages
      (measurements and triggers) MUST be protected from off-path attacks.
      Without protection, it could be trivial for an attacker to inject fake
      or modified control/measurement messages (e.g., indicating high packet
      loss rates) causing a CB to trigger and therefore to mount
      a DoS attack that disrupts a flow.</t>

      <t>Simple protection can be provided by using a randomized source port,
      or equivalent field in the packet header (such as the RTP SSRC value and
      the RTP sequence number) expected not to be known to an off-path
      attacker. Stronger protection can be achieved using a secure
      authentication protocol to mitigate this concern.</t>

      <t>An attack on the control messages is relatively easy for an attacker
      on the control path when the messages are neither encrypted nor
      authenticated. Use of a cryptographic authentication mechanism for all
      control/measurement messages is RECOMMENDED to mitigate this concern,
      and would also provide protection from off-path attacks. There is a
      design trade-off between the cost of introducing cryptographic security
      for control messages and the desire to protect control communication.
      For some deployment scenarios, the value of additional protection from
      DoS attacks will therefore lead to a requirement to authenticate all
      control messages.</t>

      <t>Transmission of network-control messages consumes network capacity.
      This control traffic needs to be considered in the design of a CB
      and could potentially add to network congestion. If this traffic
      is sent over a shared path, it is RECOMMENDED that this control traffic
      be prioritized to reduce the probability of loss under congestion.
      Control traffic also needs to be considered when provisioning a network
      that uses a CB.</t>

      <t>The CB MUST be designed to be robust to packet loss that
      can also be experienced during congestion/overload. Loss of control
      messages could be a side-effect of a congested network, but it also could
      arise from other causes <xref target="Require"></xref>.</t>

      <t>The security implications depend on the design of the mechanisms, the
      type of traffic being controlled and the intended deployment scenario.
      Each design of a CB MUST therefore evaluate whether the
      particular CB mechanism has new security implications.</t>
    </section>


  </middle>

  <!--  *****BACK MATTER ***** -->

  <back>
    <!-- -->

    <references title="Normative References">
      <?rfc sortrefs="yes"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.2119.xml"?>
      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.3168.xml"?>

<!--I-D.ietf-tsvwg-rfc5405bis; Companion document; RFC 8085 -->

<reference anchor='RFC8085' target='http://www.rfc-editor.org/info/rfc8085'>
<front>
<title>UDP Usage Guidelines</title>

<author initials='L' surname='Eggert' fullname='Lars Eggert'>
    <organization />
</author>

<author initials='G' surname='Fairhurst' fullname='Gorry Fairhurst'>
    <organization />
</author>

<author initials='G' surname='Shepherd' fullname='Greg Shepherd'>
    <organization />
</author>

<date month='March' year='2017' />

<abstract><t>The User Datagram Protocol (UDP) provides a minimal message-passing transport that has no inherent congestion control mechanisms.  This document provides guidelines on the use of UDP for the designers of applications, tunnels and other protocols that use UDP.  Congestion control guidelines are a primary focus, but the document also provides guidance on other topics, including message sizes, reliability, checksums, middlebox traversal, the use of ECN, DSCPs, and ports.  Because congestion control is critical to the stable operation of the Internet, applications and other protocols that choose to use UDP as an Internet transport must employ mechanisms to prevent congestion collapse and to establish some degree of fairness with concurrent traffic.  They may also need to implement additional mechanisms, depending on how they use UDP.  Some guidance is also applicable to the design of other protocols (e.g., protocols layered directly on IP or via IP-based tunnels), especially when these protocols do not themselves provide congestion control.  This document obsoletes RFC5405 and adds guidelines for multicast UDP usage.</t></abstract>

</front>
<seriesInfo name='BCP' value='145' />
<seriesInfo name='RFC' value='8085' />
<seriesInfo name="DOI" value="10.17487/RFC8085"/>
</reference>


 
    </references>

    <references title="Informative References">


      <reference anchor="Jacobson88">
        <front>
          <title>Congestion Avoidance and Control</title>

          <author fullname="Van Jacobson" initials="V" surname="Jacobson">
            <organization>Lawrence Berkeley Network Labs</organization>
          </author>

          <date month="August" year="1988" />
        </front>

        <seriesInfo name="SIGCOMM Symposium proceedings on Communications architectures and"
                    value="protocols" />
      </reference>


<!--I-D.ietf-avtcore-rtp-circuit-breakers; In REF state as of 1/4/17; RFC 8083-->

      <reference anchor="RFC8083" target='http://www.rfc-editor.org/info/rfc8083'>
        <front>
          <title>Multimedia Congestion Control: Circuit Breakers for Unicast
          RTP Sessions</title>

          <author fullname="C. S. Perkins" initials="C.S." surname="Perkins">
            <organization></organization>

            <address>
              <postal>
                <street></street>

                <city></city>

                <region></region>

                <code></code>

                <country></country>
              </postal>

              <phone></phone>

              <facsimile></facsimile>

              <email></email>

              <uri></uri>
            </address>
          </author>

          <author fullname="V. Singh" initials="V." surname="Singh">
            <organization></organization>
          </author>

          <date month="March" year="2017" />
        </front>
<seriesInfo name='RFC' value='8083' />
<seriesInfo name="DOI" value="10.17487/RFC8083"/>
      </reference>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.1112.xml"
?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.2309.xml"
?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.2914.xml"
?>

      <?rfc ?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.3985.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.4448.xml"?>

      <?rfc ?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.4553.xml"
?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.4601.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5086.xml"
?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5087.xml"
?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5348.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.5681.xml"?>

      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.6679.xml"?>

<!--I-D.ietf-pals-congcons; now RFC 7893-->
      <?rfc include="http://xml.resource.org/public/rfc/bibxml/reference.RFC.7893.xml"?>

 
<!--I-D.ietf-tsvwg-tunnel-congestion-feedback; I-D exists -->



<reference anchor='CONGESTION-FEEDBACK'>
<front>
<title>Tunnel Congestion Feedback</title>

<author initials='X' surname='Wei' fullname='Xinpeng Wei'>
    <organization />
</author>

<author initials='L' surname='Zhu' fullname='Lei Zhu'>
    <organization />
</author>

<author initials='L' surname='Deng' fullname='Lingli Deng'>
    <organization />
</author>

<date month='September' day='30' year='2016' />

<abstract><t>This document describes a mechanism to calculate congestion of a tunnel segment based on RFC6040 recommendations, and a feedback protocol by which to send the measured congestion of the tunnel from egress to ingress . A basic  model for measuring tunnel congestion and feedback is described, and a protocol for carrying the feedback data is outlined.</t></abstract>

</front>

<seriesInfo name='Work in Progress,' value='draft-ietf-tsvwg-tunnel-congestion-feedback-03' />

</reference>

      <?rfc ?>
    </references>

    <section title="Acknowledgments" numbered="no">
      <t>There are many people who have discussed and described the issues
      that have motivated this document. Contributions and comments included:
      Lars Eggert, Colin Perkins, David Black, Matt Mathis, Andrew McGregor,
      Bob Briscoe, and Eliot Lear. This work was partly funded by the European
      Community under its Seventh Framework Programme through the Reducing
      Internet Transport Latency (RITE) project (ICT-317700).</t>
    </section>
  </back>
</rfc>