<?xml version="1.0" encoding="US-ASCII"?>
<!DOCTYPE rfc SYSTEM "rfc2629.dtd" [
<!ENTITY rfc2119 PUBLIC '' 'reference.RFC.2119.xml'>
<!ENTITY rfc5226 PUBLIC '' 'reference.RFC.5226.xml'>
<!ENTITY rfc2578 PUBLIC '' 'reference.RFC.2578.xml'>
<!ENTITY rfc2579 PUBLIC '' 'reference.RFC.2579.xml'>
<!ENTITY rfc2580 PUBLIC '' 'reference.RFC.2580.xml'>
<!ENTITY rfc1628 PUBLIC '' 'reference.RFC.1628.xml'>
<!ENTITY rfc3410 PUBLIC '' 'reference.RFC.3410.xml'>
<!ENTITY rfc3411 PUBLIC '' 'reference.RFC.3411.xml'>
<!ENTITY rfc3414 PUBLIC '' 'reference.RFC.3414.xml'>
<!ENTITY rfc3826 PUBLIC '' 'reference.RFC.3826.xml'>
<!ENTITY rfc5591 PUBLIC '' 'reference.RFC.5591.xml'>
<!ENTITY rfc5592 PUBLIC '' 'reference.RFC.5592.xml'>
<!ENTITY rfc6353 PUBLIC '' 'reference.RFC.6353.xml'>
<!ENTITY rfc6933 PUBLIC '' 'reference.RFC.6933.xml'>
<!ENTITY rfc6988 PUBLIC '' 'reference.RFC.6988.xml'>
<!ENTITY rfc7326 PUBLIC '' 'reference.RFC.7326.xml'>
<!ENTITY rfc7460 PUBLIC '' 'reference.RFC.7460.xml'>
]>
<?rfc rfcedstyle="yes"?>
<?rfc toc="yes"?>
<?rfc tocompact="no"?>
<?rfc compact="yes"?>
<?rfc subcompact="no"?>
<?rfc symrefs="yes"?>
<?rfc sortrefs="yes"?>
<rfc category="std" number="7577" ipr="trust200902" submissionType="IETF" consensus="yes">
  <front>
    <title abbrev="Battery MIB">Definition of Managed Objects for Battery Monitoring</title>

    <author fullname="Juergen Quittek" initials="J."
            surname="Quittek">
      <organization>NEC Europe, Ltd.</organization>

      <address>
        <postal>
          <street>NEC Laboratories Europe</street>

          <street>Network Research Division</street>

          <street>Kurfuersten-Anlage 36</street>

          <code>69115</code>

          <city>Heidelberg</city>

          <country>Germany</country>
        </postal>

        <phone>+49 6221 4342-115</phone>

        <email>quittek@neclab.eu</email>
      </address>
    </author>

    <author fullname="Rolf Winter" initials="R." surname="Winter">
      <organization>NEC Europe, Ltd.</organization>

      <address>
        <postal>
          <street>NEC Laboratories Europe</street>

          <street>Network Research Division</street>

          <street>Kurfuersten-Anlage 36</street>

          <code>69115</code>

          <city>Heidelberg</city>

          <country>Germany</country>
        </postal>

        <phone>+49 6221 4342-121</phone>

        <email>Rolf.Winter@neclab.eu</email>
      </address>
    </author>

    <author fullname="Thomas Dietz" initials="T." surname="Dietz">
      <organization>NEC Europe, Ltd.</organization>

      <address>
        <postal>
          <street>NEC Laboratories Europe</street>

          <street>Network Research Division</street>

          <street>Kurfuersten-Anlage 36</street>

          <code>69115</code>

          <city>Heidelberg</city>

          <country>Germany</country>
        </postal>

        <phone>+49 6221 4342-128</phone>

        <email>Thomas.Dietz@neclab.eu</email>
      </address>
    </author>
  <date month="June" year="2015" />

    <abstract>
      <t>This memo defines a portion of the Management Information Base (MIB)
      for use with network management protocols in the Internet community. In
      particular, it defines managed objects that provide information 
      on the status of batteries in managed devices.</t>
    </abstract>
  </front>

  <middle>
    <section title="Introduction">
      <t>Today, more and more managed devices contain batteries that supply them
      with power when disconnected from electrical power distribution grids. 
      Common examples are nomadic and mobile devices, such as notebook 
      computers, netbooks, and smartphones.  The status of batteries in such
      a device, particularly the charging status, is typically controlled by 
      automatic functions that act locally on the device and manually by users 
      of the device.</t>

      <t>In addition to this, there is a need to monitor battery status of 
      these devices by network management systems. This document defines a 
      portion of the Management Information Base (MIB) that provides a means 
      for monitoring batteries in or attached to managed devices. The Battery
      MIB module defined in <xref target="definitions"/> meets the 
      requirements for monitoring the status of batteries specified in 
      <xref target="RFC6988">RFC 6988</xref>.</t>
      
      <t>The Battery MIB module provides for monitoring the battery status. 
      According to the <xref target="RFC7326">framework for
      energy management</xref>, it is an Energy Managed Object; thus, MIB modules such as
      the <xref target="RFC7460">Power and Energy Monitoring MIB</xref>
      could, in principle, be implemented for batteries. 
      The Battery MIB extends the more generic aspects of energy management by adding
      battery-specific information. Amongst other things, the Battery MIB enables
      the monitoring of:</t>

      <t><list style="symbols">
        <t>the current charge of a battery,</t>
        <t>the age of a battery (charging cycles),</t>
        <t>the state of a battery (e.g., being recharged),</t>
        <t>last usage of a battery, and</t>              
        <t>maximum energy provided by a battery (remaining and total capacity).</t>
      </list></t>
      
      <t>Further, means are provided for battery-powered devices
      to send notifications to inform the management system of needed replacement when the current battery charge has dropped below a 
      certain threshold. The same applies to the age of a battery.</t>
      
      <t>Many battery-driven devices have existing instrumentation 
      for monitoring the battery status because this is already needed 
      for local control of the battery by the device. This reduces the effort
      for implementing the managed objects defined in this document. For many
      devices, only additional software will be needed; no additional hardware
      instrumentation for battery monitoring is necessary.</t>
      
      <t>Since there are a lot of devices in use that contain more than
      one battery, means for battery monitoring defined in this document
      support addressing multiple batteries within a single device. 
      Also, batteries today often come in packages that can include identification 
      and might contain additional hardware and firmware. The former allows
      tracing a battery and allows continuous monitoring even if the battery
      is installed in another device. The firmware version is useful
      information as the battery behavior might be different for different
      firmware versions.</t>

      <t>Not explicitly in the scope of definitions in this document are very 
      small backup batteries, for example, batteries used on a PC 
      motherboard to run the clock circuit and retain configuration memory 
      while the system is turned off. Other means may be required for 
      reporting on these batteries. However, the MIB module defined in 
      <xref target="mibStructure"/> can be used for this purpose.</t>
      
      <t>A traditional type of managed device containing batteries is 
      an Uninterruptible Power Supply (UPS) system; these supply other devices 
      with electrical energy when the main power supply fails. There is already
      a MIB module for managing UPS systems defined in 
      <xref target="RFC1628">RFC 1628</xref>. The UPS MIB module includes 
      managed objects for monitoring the batteries contained in a UPS system.  
      However, the information provided by the UPS MIB objects is limited and 
      tailored to the particular needs of UPS systems.</t>
      
      <t>A huge variety of battery technologies are available, and they are evolving over time.
      For different applications, different battery technologies are preferable,
      for example, because of different weight, cost, robustness, charging time, etc.
      Some technologies, such as lead-acid batteries, are continuously in use for decades, 
      while others, such as nickel-based battery technologies (nickel-cadmium and 
      nickel-metal hydride), have, to a wide extent, been replaced by lithium-based 
      battery technologies (lithium-ion and lithium polymer).</t>
      
      <t> The Battery MIB module uses a generic abstraction of batteries that is 
      independent of particular battery technologies and expected to be applicable 
      to future technologies as well.  While identification of a particular battery 
      technology is supported by an extensible list of battery technology identifiers
      (see <xref target="technologies"/>), individual properties of the technologies 
      are not modeled by the abstraction. In particular, methods for charging a battery,
      and the parameters of those methods, which vary greatly between different technologies are not
      individually modeled.</t>

      <t>Instead, the Battery MIB module uses a simple common 
      charging model with batteries being in one of the following states: 'charging', 
      'maintaining charge', 'not charging', and 'discharging'. Control of the 
      charging process is limited to requests for transitions between these states.
      For charging controllers that use charging state engines with more states,
      implementations of the Battery MIB module need to map those states to the four 
      listed above.</t>
      
      <t>For energy management systems that require finer-grained control of 
      the battery charging process, additional means need to be developed; 
      for example, MIB modules that model richer sets of charging 
      states and parameters for charging states.</t>

      <t>All use cases sketched above assume that the batteries 
      are contained in a managed entity. In a typical case, 
      this entity also hosts the SNMP applications (command responder and
      notification generator) and the charging controller for 
      contained batteries. For definitions in this document, it 
      is not strictly required that batteries be contained in 
      the same managed entity, even though the Battery MIB module 
      (defined further below) uses the containment tree of the 
      <xref target="RFC6933">Entity MIB module</xref> for battery indexing.</t> 

      <t>External batteries can be supported as long as the charging 
      controller for these batteries is connected to the SNMP 
      applications that implement the Battery MIB module. An example 
      with an external battery is shown in the figure below. It
      illustrates that the Battery MIB module is designed as an interface 
      between the management system and battery charging controller.       
      Out of scope of this document is the interface between the 
      battery charging controller and controlled batteries.</t>

      <figure anchor="fig-external" 
            title="Battery MIB as Interface between Management System and Battery-Charging Controller Supporting External Batteries">
        <artwork><![CDATA[
              +-----------------------------------+
              |         management system         |
              +-----------------+-----------------+
                                |
                                | Battery MIB
                                |
              +-----------------+-----------------+
              | managed element |                 |
              |                 |                 |
              |  +--------------+--------------+  |
              |  | battery charging controller |  |
              |  +-----+--------------+--------+  |
              |        |              |           |
              |  +-----+-----+        |           |
              |  | internal  |        |           |
              |  | battery   |        |           |
              |  +-----------+        |           |
              +-----------------------+-----------+
                                      |
                                +-----+-----+
                                | external  |
                                | battery   |
                                +-----------+
        ]]></artwork>
      </figure>                

      <t>The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
      "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL" in this
      document are to be interpreted as described in <xref target="RFC2119">
      RFC 2119</xref>.</t>
    </section>
<!--Begin DNE text  --> 
    <section title="The Internet-Standard Management Framework">
      <t>For a detailed overview of the documents that describe the current
      Internet-Standard Management Framework, please refer to section 7 of
      <xref target="RFC3410">RFC 3410</xref>.</t>

      <t>Managed objects are accessed via a virtual information store, termed
      the Management Information Base or MIB. MIB objects are generally
      accessed through the Simple Network Management Protocol (SNMP). Objects
      in the MIB are defined using the mechanisms defined in the Structure of
      Management Information (SMI). This memo specifies MIB modules that are
      compliant to the SMIv2, which is described in STD 58, <xref
      target="RFC2578">RFC 2578</xref>, STD 58, <xref target="RFC2579"> RFC
      2579</xref> and STD 58,<xref target="RFC2580"> RFC 2580</xref>.</t>
<!--End DNE text  --> 
    </section>

    <section anchor="mibOverview" title="Design of the Battery MIB Module">
      <section anchor="mibStructure" title="MIB Module Structure">
        <t>The Battery MIB module defined in this document defines objects for
        reporting information about batteries. All managed objects providing
        information on the status of a battery are contained in a single table
        called "batteryTable". The batteryTable contains one conceptual row 
        per battery.</t>

        <t>Batteries are indexed by the entPhysicalIndex of the 
        entPhysicalTable defined in the <xref target="RFC6933">Entity MIB
        module</xref>.  An implementation of the Entity MIB module complying 
        with the entity4CRCompliance MODULE-COMPLIANCE statement is required 
        for compliant implementations of the Battery MIB module.</t>
        
        <t>If a battery is replaced, and the replacing battery uses 
        the same physical connector as the replaced battery, then 
        the replacing battery MUST be indexed with the same value 
        of object entPhysicalIndex as the replaced battery.</t>

        <t>The kind of entity in the entPhysicalTable of the Entity MIB 
        module is indicated by the value of enumeration object entPhysicalClass. 
        All batteries SHOULD have the value of object entPhysicalClass set to 
        battery(14) in their row of the entPhysicalTable.</t>

        <t>The batteryTable contains three groups of objects. The first group
        (OIDs ending with 1-9) provides information on static properties of the 
        battery. The second group of objects (OIDs ending with 10-18) provides
        information on the current battery state, if it is charging or 
        discharging, how much it is charged, its remaining capacity, the number 
        of experienced charging cycles, etc.</t>


        <figure>
          <artwork><![CDATA[
   batteryTable(1)
   +--batteryEntry(1) [entPhysicalIndex]
      +-- r-n SnmpAdminString batteryIdentifier(1)
      +-- r-n SnmpAdminString batteryFirmwareVersion(2)
      +-- r-n Enumeration     batteryType(3)
      +-- r-n Unsigned32      batteryTechnology(4)
      +-- r-n Unsigned32      batteryDesignVoltage(5)
      +-- r-n Unsigned32      batteryNumberOfCells(6)
      +-- r-n Unsigned32      batteryDesignCapacity(7)
      +-- r-n Unsigned32      batteryMaxChargingCurrent(8)
      +-- r-n Unsigned32      batteryTrickleChargingCurrent(9)
      +-- r-n Unsigned32      batteryActualCapacity(10)
      +-- r-n Unsigned32      batteryChargingCycleCount(11)
      +-- r-n DateAndTime     batteryLastChargingCycleTime(12)
      +-- r-n Enumeration     batteryChargingOperState(13)
      +-- rwn Enumeration     batteryChargingAdminState(14)
      +-- r-n Unsigned32      batteryActualCharge(15)
      +-- r-n Unsigned32      batteryActualVoltage(16)
      +-- r-n Integer32       batteryActualCurrent(17)
      +-- r-n Integer32       batteryTemperature(18)
      +-- rwn Unsigned32      batteryAlarmLowCharge(19)
      +-- rwn Unsigned32      batteryAlarmLowVoltage(20)
      +-- rwn Unsigned32      batteryAlarmLowCapacity(21)
      +-- rwn Unsigned32      batteryAlarmHighCycleCount(22)
      +-- rwn Integer32       batteryAlarmHighTemperature(23)
      +-- rwn Integer32       batteryAlarmLowTemperature(24)
      +-- r-n SnmpAdminString batteryCellIdentifier(25)
          ]]></artwork>
        </figure>

        <t>The third group of objects in this table (OIDs ending with 19-25) 
        is used for notifications. Threshold objects (OIDs ending with 19-24)
        indicate thresholds that can be used to raise an alarm if a property 
        of the battery exceeds one of them. Raising an alarm may include 
        sending a notification.</t>
      
        <t>The Battery MIB defines seven notifications for indicating:</t>
        
        <t><list style="numbers">
          <t>a battery-charging state change that was not triggered by writing 
          to object batteryChargingAdminState,</t>
          <t>a low-battery charging state,</t>
          <t>a critical-battery state in which it cannot be used for power supply,</t>
          <t>an aged battery that may need to be replaced,</t>
          <t>a battery that has exceeded a temperature threshold,</t>              
          <t>a battery that has been connected, and</t>
          <t>disconnection of one or more batteries.</t>
        </list></t>
        
        <t>Notifications 2-5 can use object batteryCellIdentifier
        to indicate a specific cell or a set of cells within the battery
        that have triggered the notification.</t>
      </section>

      <section anchor="technologies" title="Battery Technologies">
        <t>Static information in the batteryTable includes battery type and 
        technology. The battery type distinguishes primary (not rechargeable)
        batteries from rechargeable (secondary) batteries and capacitors. 
        The battery technology describes the actual technology of a battery, 
        which typically is a chemical technology.</t>
      
        <t>Since battery technologies are the subject of intensive research and
        widely used technologies are often replaced by successor technologies 
        within a few years, the list of battery technologies was not chosen
        as a fixed list. Instead, IANA has created a registry for battery 
        technologies at &lt;http://www.iana.org/assignments/battery-technologies&gt; 
        where numbers are assigned to battery technologies.</t>
      
        <t>The table below shows battery technologies known today that
        are in commercial use with the numbers assigned to them by IANA. 
        New entries can be added to the IANA registry if new technologies 
        are developed or if missing technologies are identified. Note that 
        there exists a huge number of battery types that are not listed 
        in the IANA registry. Many of them are experimental or cannot 
        be used in an economically useful way. New entries should be 
        added to the IANA registry only if the respective technologies 
        are in commercial use and relevant to standardized battery 
        monitoring over the Internet.</t>
 
        <figure>
          <artwork><![CDATA[
   +--------------------------------+---------------+
   | Battery Technology             |      Value    |
   +--------------------------------+---------------+
   | Reserved                       |             0 |
   | Unknown                        |             1 |
   | Other                          |             2 |
   | Zinc-carbon                    |             3 |
   | Zinc chloride                  |             4 |
   | Nickel oxyhydroxide            |             5 |
   | Lithium-copper oxide           |             6 |
   | Lithium-iron disulfide         |             7 |
   | Lithium-manganese dioxide      |             8 |
   | Zinc-air                       |             9 |
   | Silver oxide                   |            10 |
   | Alkaline                       |            11 |
   | Lead-acid                      |            12 |
   | Valve-Regulated Lead-Acid, Gel |            13 |
   | Valve-Regulated Lead-Acid, AGM |            14 |
   | Nickel-cadmium                 |            15 |
   | Nickel-metal hydride           |            16 |
   | Nickel-zinc                    |            17 |
   | Lithium-ion                    |            18 |
   | Lithium polymer                |            19 |
   | Double layer capacitor         |            20 |
   | Unassigned                     | 21-4294967295 |
   +--------------------------------+---------------+
          ]]></artwork>
        </figure>

        <section anchor="iana-guidelines" 
        title="Guidelines for Adding Battery Technologies">
          <t>New entries can be added to the IANA registry if new technologies 
          are developed or if missing technologies are identified. Note that 
          there exists a huge number of battery types that are not listed 
          in the IANA registry. Many of them are experimental or cannot 
          be used in an economically useful way. New entries should be 
          added to the IANA registry only if the respective technologies 
          are in commercial use and relevant to standardized battery 
          monitoring over the Internet.</t>     
        </section>
      </section>

      <section anchor="identification" title="Battery Identification">
         <t>There are two identifiers to be used: the entPhysicalUUID 
          defined in the <xref target="RFC6933">Entity MIB</xref> module 
          and the batteryIdentifier defined in this module. A battery is 
          linked to an entPhysicalUUID through the shared entPhysicalIndex.</t>
          
         <t>The batteryIdentifier uniquely identifies the battery itself
          while the entPhysicalUUID identifies the slot of the device in 
          which the battery is (currently) contained. For a non-replaceable 
          battery, both identifiers are always linked to the same physical 
          battery. But for batteries that can be replaced, the identifiers 
          have different functions.</t>
          
         <t>The entPhysicalUUID is always the same for a certain battery 
          slot of a containing device even if the contained battery
          is replaced by another. The batteryIdentifier is a 
          representation of the battery identifier set by the battery 
          manufacturer. It is tied to the battery and usually cannot be 
          changed.</t>
          
         <t>Many manufacturers deliver not just plain batteries but battery 
          packages including additional hardware and firmware. Typically, 
          these modules include a battery identifier that can by retrieved 
          by a device in which a battery has been installed. The value of 
          the object batteryIdentifier is an exact representation of this 
          identifier. The batteryIdentifier is useful when batteries are 
          removed and reinstalled in the same device or in other devices. 
          Then, the device or the network management system can trace 
          batteries and achieve continuity of battery monitoring.</t> 
      </section>      
       
      <section anchor="cycles" title="Charging Cycles">
        <t>The lifetime of a battery can be approximated using the measure of 
         charging cycles. A commonly used definition of a charging cycle
         is the amount of discharge equal to the design (or nominal) capacity of the battery
         <xref target="SBS"/>. This means that a single charging cycle 
         may include several steps of partial charging and discharging 
         until the amount of discharging has reached the design capacity of the 
         battery. After that, the next charging cycle immediately starts.</t>
      </section>
       
      <section anchor="adminState" title="Charge Control">
        <t>Managed object batteryChargingOperState indicates the current
          operational charging state of a battery and is a read-only object. 
          For controlling the charging state, object batteryChargingAdminState
          can be used. Writing to this object initiates a request to adapt
          the operational state according to the value that has been written.
        </t>
        <t>By default, the batteryChargingAdminState object is set to notSet(1).
          In this state, the charging controller is using its predefined policies
          to decide which operational state is suitable in the current situation.
        </t>
        <t>Setting the value of object batteryChargingAdminState may result in 
          not changing the state of the battery to this value or even in setting
          the charging state to another value than the requested one. Due to
          operational conditions and limitations of the implementation of the
          Battery MIB module, changing the battery status according to a set
          value of object batteryChargingAdminState might not be possible. For
          example, the charging controller might, at any time, decide to enter
          state discharging(5), if there is an operational need to use the battery for
          supplying power.
        </t>
        <t>The object batteryChargingAdminState will not automatically change when
          the object batteryChargingOperState changes. If the operational state
          is changed, e.g., to the state discharging(5) due to operational conditions, the
          admin state will remain in its current state. The charging controller
          SHOULD change the operational state to the state indicated by the
          object batteryChargingAdminState as soon as operational conditions
          allow this change.
        </t>
        <t>If a state change of the object batteryChargingAdminState is desired
          upon change of the operational state, the object
          batteryChargingOperState must be polled or the notification
          batteryChargingStateNotification must be used to get notified about
          the state change. This could be used, e.g., if maintaining charge is
          not desired after fully charging a battery even if the charging controller
          and battery support it. The object batteryChargingAdminState can then
          be set to doNotCharge(3) when the object batteryChargingOperState
          changes from charging(2) to maintainingCharge(3). Another use case
          would be when performing several charge and discharge cycles for
          battery maintenance.
        </t>
      </section>
      
      <section anchor="imports" title="Imported Definitions">
        <t>The BATTERY-MIB module defined in this document imports definitions from 
        the following MIB modules: 
        <xref target="RFC2578">SNMPv2-SMI</xref>,
        <xref target="RFC2579">SNMPv2-TC</xref>,
        <xref target="RFC2580">SNMPv2-CONF</xref>,
        <xref target="RFC3411">SNMP-FRAMEWORK-MIB</xref>, and
        <xref target="RFC6933">ENTITY-MIB</xref>.
        </t>
       </section>
      </section>

    <section title="Definitions" anchor="definitions">

<figure><artwork><![CDATA[
BATTERY-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, 
    mib-2, Integer32, Unsigned32
        FROM SNMPv2-SMI                                -- RFC 2578
    DateAndTime
        FROM SNMPv2-TC                                 -- RFC 2579
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
        FROM SNMPv2-CONF                               -- RFC 2580
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB                        -- RFC 3411
    entPhysicalIndex
        FROM ENTITY-MIB;                               -- RFC 6933

batteryMIB MODULE-IDENTITY
    LAST-UPDATED "201506151200Z"         -- 15 June 2015
    ORGANIZATION "IETF EMAN Working Group"
    CONTACT-INFO
        "General Discussion: eman@ietf.org
        To Subscribe: <http://www.ietf.org/mailman/listinfo/eman>
        Archive: <http://www.ietf.org/mail-archive/web/eman>

        Editor:
          Juergen Quittek
          NEC Europe, Ltd.
          NEC Laboratories Europe
          Kurfuersten-Anlage 36
          69115 Heidelberg
          Germany
          Tel: +49 6221 4342-115
          Email: quittek@neclab.eu"

    DESCRIPTION
        "This MIB module defines a set of objects for monitoring
        batteries of networked devices and of their components.

        Copyright (c) 2015 IETF Trust and the persons identified as
        authors of the code.  All rights reserved.

        Redistribution and use in source and binary forms, with or 
        without modification, is permitted pursuant to, and subject 
        to the license terms contained in, the Simplified BSD License 
        set forth in Section 4.c of the IETF Trust's Legal Provisions 
        Relating to IETF Documents 
        (http://trustee.ietf.org/license-info). 

        This version of this MIB module is part of RFC 7577; see
        the RFC itself for full legal notices."
--  Revision history

    REVISION "201506151200Z"         -- 15 June 2015
    DESCRIPTION
        "Initial version published as RFC 7577."

    ::= { mib-2 233 }


--******************************************************************
-- Top-Level Structure of the MIB Module
--******************************************************************

batteryNotifications OBJECT IDENTIFIER ::= { batteryMIB 0 }
batteryObjects       OBJECT IDENTIFIER ::= { batteryMIB 1 }
batteryConformance   OBJECT IDENTIFIER ::= { batteryMIB 2 }

--==================================================================
-- 1.  Object Definitions
--==================================================================

--------------------------------------------------------------------
-- 1.1.  Battery Table
--------------------------------------------------------------------
batteryTable  OBJECT-TYPE
    SYNTAX      SEQUENCE OF BatteryEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table provides information on batteries.  It contains 
        one conceptual row per battery in a managed entity.  
        
        Batteries are indexed by the entPhysicalIndex of the 
        entPhysicalTable defined in the ENTITY-MIB (RFC 6933).  
        
        For implementations of the BATTERY-MIB, an implementation of 
        the ENTITY-MIB complying with the entity4CRCompliance 
        MODULE-COMPLIANCE statement of the ENTITY-MIB is required.
        
        If batteries are replaced, and the replacing battery uses 
        the same physical connector as the replaced battery, then 
        the replacing battery SHOULD be indexed with the same value 
        of object entPhysicalIndex as the replaced battery."
    ::= { batteryObjects 1 }

batteryEntry OBJECT-TYPE
    SYNTAX      BatteryEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry providing information on a battery."
    INDEX  { entPhysicalIndex }
    ::= { batteryTable 1 }

BatteryEntry ::=
    SEQUENCE {
       batteryIdentifier               SnmpAdminString,
       batteryFirmwareVersion          SnmpAdminString,
       batteryType                     INTEGER,
       batteryTechnology               Unsigned32,
       batteryDesignVoltage            Unsigned32,
       batteryNumberOfCells            Unsigned32,
       batteryDesignCapacity           Unsigned32,
       batteryMaxChargingCurrent       Unsigned32,
       batteryTrickleChargingCurrent   Unsigned32,
       batteryActualCapacity           Unsigned32,
       batteryChargingCycleCount       Unsigned32,
       batteryLastChargingCycleTime    DateAndTime,
       batteryChargingOperState        INTEGER,
       batteryChargingAdminState       INTEGER,
       batteryActualCharge             Unsigned32,
       batteryActualVoltage            Unsigned32,
       batteryActualCurrent            Integer32,
       batteryTemperature              Integer32,
       batteryAlarmLowCharge           Unsigned32,
       batteryAlarmLowVoltage          Unsigned32,
       batteryAlarmLowCapacity         Unsigned32,
       batteryAlarmHighCycleCount      Unsigned32,
       batteryAlarmHighTemperature     Integer32,
       batteryAlarmLowTemperature      Integer32,
       batteryCellIdentifier           SnmpAdminString
    }

batteryIdentifier OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object contains an identifier for the battery.
        
        Many manufacturers deliver not only simple batteries but 
        battery packages including additional hardware and firmware.
        Typically, these modules include an identifier that can be
        retrieved by a device in which a battery has been installed.
        The identifier is useful when batteries are removed and
        reinstalled in the same or other devices.  Then, the device
        or the network management system can trace batteries and
        achieve continuity of battery monitoring.

        If the battery is identified by more than one value, 
        for example, by a model number and a serial number, 
        then the value of this object is a concatenation of these 
        values, separated by the colon symbol ':'.  The values 
        should be ordered so that a more significant value comes 
        before a less significant one.  In the example above, the 
        (more significant) model number would be first, and the serial 
        number would follow: '<model number>:<serial number>'.

        If the battery identifier cannot be represented using the
        ISO/IEC IS 10646-1 character set, then a hexadecimal
        encoding of a binary representation of the entire battery
        identifier must be used.

        The value of this object must be an empty string if there 
        is no battery identifier or if the battery identifier is 
        unknown."
    ::= { batteryEntry 1 }

batteryFirmwareVersion OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the version number of the firmware
        that is included in a battery module.

        Many manufacturers deliver not pure batteries but battery
        packages including additional hardware and firmware. 

        Since the behavior of the battery may change with the
        firmware, it may be useful to retrieve the firmware version
        number.
        
        The value of this object must be an empty string if there 
        is no firmware or if the version number of the firmware is 
        unknown."
    ::= { batteryEntry 2 }

batteryType OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(1),
                    other(2),
                    primary(3),
                    rechargeable(4),
                    capacitor(5)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the type of battery.  
        It distinguishes between primary (not rechargeable)  
        batteries, rechargeable (secondary) batteries, and 
        capacitors.  Capacitors are not really batteries but 
        are often used in the same way as a battery.
        
        The value other(2) can be used if the battery type is known
        but is none of the ones above.  Value unknown(1) is to be used
        if the type of battery cannot be determined."
    ::= { batteryEntry 3 }

batteryTechnology OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the technology used by the battery.
        Numbers identifying battery technologies are registered at  
        IANA.  A current list of assignments can be found at
        <http://www.iana.org/assignments/battery-technologies>.

        Value unknown(1) MUST be used if the technology of the 
        battery cannot be determined. 
        
        Value other(2) can be used if the battery technology is known
        but is not one of the types already registered at IANA."
    ::= { batteryEntry 4 }

batteryDesignVoltage OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "millivolt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object provides the design (or nominal) voltage of the 
        battery in units of millivolt (mV). 
        
        Note that the design voltage is a constant value and
        typically different from the actual voltage of the battery. 

        A value of 0 indicates that the design voltage is unknown."
    ::= { batteryEntry 5 }

batteryNumberOfCells OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the number of cells contained in the
        battery. 
        
        A value of 0 indicates that the number of cells is unknown."
    ::= { batteryEntry 6 }

batteryDesignCapacity OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliampere hours"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object provides the design (or nominal) capacity of 
        the battery in units of milliampere hours (mAh). 
        
        Note that the design capacity is a constant value and
        typically different from the actual capacity of the battery.
        Usually, this is a value provided by the manufacturer of the
        battery. 

        A value of 0 indicates that the design capacity is 
        unknown."
    ::= { batteryEntry 7 }

batteryMaxChargingCurrent OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object provides the maximum current to be used for
        charging the battery in units of milliampere (mA). 
        
        Note that the maximum charging current may not lead to
        optimal charge of the battery and that some batteries can
        only be charged with the maximum current for a limited
        amount of time. 

        A value of 0 indicates that the maximum charging current is 
        unknown."
    ::= { batteryEntry 8 }

batteryTrickleChargingCurrent OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object provides the recommended average current 
        to be used for trickle charging the battery in units of 
        mA. 
        
        Typically, this is a value recommended by the manufacturer
        of the battery or by the manufacturer of the charging 
        circuit. 

        A value of 0 indicates that the recommended trickle charging
        current is unknown."
    ::= { batteryEntry 9 }

batteryActualCapacity OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliampere hours"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object provides the actual capacity of the
        battery in units of mAh.

        Typically, the actual capacity of a battery decreases
        with time and with usage of the battery.  It is usually
        lower than the design capacity.

        Note that the actual capacity needs to be measured and is
        typically an estimate based on observed discharging and
        charging cycles of the battery.

        A value of 'ffffffff'H indicates that the actual capacity
        cannot be determined."
    ::= { batteryEntry 10 }

batteryChargingCycleCount OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the number of completed charging 
        cycles that the battery underwent.  In line with the 
        Smart Battery Data Specification Revision 1.1, a charging 
        cycle is defined as the process of discharging the battery 
        by a total amount equal to the battery design capacity as 
        given by object batteryDesignCapacity.  A charging cycle 
        may include several steps of charging and discharging the 
        battery until the discharging amount given by 
        batteryDesignCapacity has been reached.  As soon as a 
        charging cycle has been completed, the next one starts 
        immediately, independent of the battery's current charge at 
        the end of the cycle.
  
        For batteries of type primary(3), the value of this object is 
        always 0.
        
        A value of 'ffffffff'H indicates that the number of charging
        cycles cannot be determined."
    ::= { batteryEntry 11 }

batteryLastChargingCycleTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The date and time of the last charging cycle.  The value 
        '0000000000000000'H is returned if the battery has not been
        charged yet or if the last charging time cannot be 
        determined. 
        
        For batteries of type primary(1), the value of this object is 
        always '0000000000000000'H."
    ::= { batteryEntry 12 }

batteryChargingOperState OBJECT-TYPE
    SYNTAX      INTEGER {
                    unknown(1),
                    charging(2),
                    maintainingCharge(3),
                    noCharging(4),
                    discharging(5)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the current charging state of the 
        battery.
        
        Value unknown(1) indicates that the charging state of the 
        battery cannot be determined.

        Value charging(2) indicates that the battery is being 
        charged in a way such that the charge of the battery 
        increases.
        
        Value maintainingCharge(3) indicates that the battery is 
        being charged with a low-average current that compensates 
        self-discharging.  This includes trickle charging, float 
        charging, and other methods for maintaining the current
        charge of a battery.  In typical implementations of charging
        controllers, state maintainingCharge(3) is only applied
        if the battery is fully charged or almost fully charged.
        
        Value noCharging(4) indicates that the battery is not being
        charged or discharged by electric current between the 
        battery and electric circuits external to the battery. 
        Note that the battery may still be subject to 
        self-discharging.
        
        Value discharging(5) indicates that the battery is either 
        used as the power source for electric circuits external to
        the battery or discharged intentionally by the
        charging controller, e.g., for the purpose of battery
        maintenance.  In any case, the charge of the battery
        decreases."
    ::= { batteryEntry 13 }
    
batteryChargingAdminState OBJECT-TYPE
    SYNTAX      INTEGER {
                    notSet(1),
                    charge(2),
                    doNotCharge(3),
                    discharge(4)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of this object indicates the desired 
        charging state of the battery.  The real state is 
        indicated by object batteryChargingOperState.  See the 
        definition of object batteryChargingOperState for a 
        description of the values.

        When this object is initialized by an implementation of the
        BATTERY-MIB module, its value is set to notSet(1).  In this
        case, the charging controller is free to choose which
        operational state is suitable.

        When the batteryChargingAdminState object is set, then the
        BATTERY-MIB implementation must try to set the battery
        to the indicated state.  The result will be indicated by
        object batteryChargingOperState.
        
        Setting object batteryChargingAdminState to value notSet(1)
        is a request to the charging controller to operate
        autonomously and choose the operational state that is
        suitable.
        
        Setting object batteryChargingAdminState to value charge(2)
        is a request to enter the operational state charging(2) until
        the battery is fully charged.  When the battery is fully
        charged, or if the battery was already fully charged or
        almost fully charged at the time of the request, the
        operational state will change to maintainingCharge(3) if the
        charging controller and the battery support the functionality
        of maintaining the charge, or it will change to noCharging(4)
        otherwise.
        
        Setting object batteryChargingAdminState to value 
        doNotCharge(3) is a request for entering operational 
        state noCharging(4).
        
        Setting object batteryChargingAdminState to value 
        discharge(4) is a request for entering operational 
        state discharging(5).  Discharging can be accomplished
        by ordinary use, applying a dedicated load, or any other
        means.  An example for applying this state is battery
        maintenance.  If the battery is empty or almost empty, the
        operational state will change to noCharging(4).
        The charging controller will decide which charge condition
        will be considered empty dependent on the battery
        technology used.  This is done to avoid damage on the
        battery due to deep discharge.
        
        Due to operational conditions and limitations of the
        implementation of the BATTERY-MIB module, changing the
        battery status according to a set value of object
        batteryChargingAdminState may not be possible.
        Setting the value of object batteryChargingAdminState
        may result in not changing the state of the battery
        to this value or even in setting the charging state
        to another value than the requested one.  For example,
        the charging controller might at any time decide to 
        enter state discharging(5), if there is an operational need
        to use the battery for supplying power."
    ::= { batteryEntry 14 }

batteryActualCharge OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliampere hours"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object provides the actual charge of the battery
        in units of mAh. 
        
        Note that the actual charge needs to be measured and is
        typically an estimate based on observed discharging and
        charging cycles of the battery. 

        A value of 'ffffffff'H indicates that the actual charge 
        cannot be determined."
    ::= { batteryEntry 15 }

batteryActualVoltage OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "millivolt"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object provides the actual voltage of the battery
        in units of mV. 
        
        A value of 'ffffffff'H indicates that the actual voltage 
        cannot be determined."
    ::= { batteryEntry 16 }

batteryActualCurrent OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "milliampere"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object provides the actual charging or discharging
        current of the battery in units of mA.  
        The charging current is represented by positive values, 
        and the discharging current is represented by negative values.

        A value of '7fffffff'H indicates that the actual current
        cannot be determined."
    ::= { batteryEntry 17 }

batteryTemperature OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "deci-degrees Celsius"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The ambient temperature at or within close proximity 
        of the battery.

        A value of '7fffffff'H indicates that the temperature
        cannot be determined."
    ::= { batteryEntry 18 }

batteryAlarmLowCharge OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliampere hours"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object provides the lower-threshold value for object 
        batteryActualCharge.  If the value of object 
        batteryActualCharge falls below this threshold, 
        a low-battery alarm will be raised.  The alarm procedure may
        include generating a batteryLowNotification.
        
        This object should be set to a value such that when the
        batteryLowNotification is generated, the battery is still 
        sufficiently charged to keep the device(s) that it powers 
        operational for a time long enough to take actions before 
        the powered device(s) enters a 'sleep' or 'off' state.
        
        A value of 0 indicates that no alarm will be raised for any
        value of object batteryActualVoltage."
    ::= { batteryEntry 19 }

  batteryAlarmLowVoltage OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "millivolt"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "This object provides the lower-threshold value for object
          batteryActualVoltage.  If the value of object
          batteryActualVoltage falls below this threshold,
          a low-battery alarm will be raised.  The alarm procedure may
          include generating a batteryLowNotification.

          This object should be set to a value such that when the
          batteryLowNotification is generated, the battery is still
          sufficiently charged to keep the device(s) that it powers
          operational for a time long enough to take actions before
          the powered device(s) enters a 'sleep' or 'off' state.

          A value of 0 indicates that no alarm will be raised for any
          value of object batteryActualVoltage."
      ::= { batteryEntry 20 }

batteryAlarmLowCapacity OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliampere hours"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object provides the lower-threshold value for object 
        batteryActualCapacity.  If the value of object 
        batteryActualCapacity falls below this threshold, 
        a battery aging alarm will be raised.  The alarm procedure 
        may include generating a batteryAgingNotification.
        
        A value of 0 indicates that no alarm will be raised for any
        value of object batteryActualCapacity."
    ::= { batteryEntry 21 }

batteryAlarmHighCycleCount OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object provides the upper-threshold value for object 
        batteryChargingCycleCount.  If the value of object 
        batteryChargingCycleCount rises above this threshold, 
        a battery aging alarm will be raised.  The alarm procedure 
        may include generating a batteryAgingNotification.
        
        A value of 0 indicates that no alarm will be raised for any
        value of object batteryChargingCycleCount."
    ::= { batteryEntry 22 }
    
batteryAlarmHighTemperature OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "deci-degrees Celsius"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object provides the upper-threshold value for object 
        batteryTemperature.  If the value of object
        batteryTemperature rises above this threshold, a battery 
        high temperature alarm will be raised.  The alarm procedure 
        may include generating a batteryTemperatureNotification.

        A value of '7fffffff'H indicates that no alarm will be 
        raised for any value of object batteryTemperature."
    ::= { batteryEntry 23 }

batteryAlarmLowTemperature OBJECT-TYPE
    SYNTAX      Integer32
    UNITS       "deci-degrees Celsius"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object provides the lower-threshold value for object 
        batteryTemperature.  If the value of object
        batteryTemperature falls below this threshold, a battery 
        low temperature alarm will be raised.  The alarm procedure 
        may include generating a batteryTemperatureNotification.

        A value of '7fffffff'H indicates that no alarm will be 
        raised for any value of object batteryTemperature."
    ::= { batteryEntry 24 }

batteryCellIdentifier OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The value of this object identifies one or more cells of a
        battery.  The format of the cell identifier may vary between
        different implementations.  It should uniquely identify one 
        or more cells of the indexed battery.  
        
        This object can be used for batteries, such as lithium
        polymer batteries for which battery controllers monitor
        cells individually.
        
        This object is used by notifications of types
        batteryLowNotification, batteryTemperatureNotification, 
        batteryCriticalNotification, and batteryAgingNotification.  
        These notifications can use the value of this object to 
        indicate the event that triggered the generation of the 
        notification in more detail by specifying a single cell 
        or a set of cells within the battery that is specifically 
        addressed by the notification.
        
        An example use case for this object is a single cell in a 
        battery that exceeds the temperature indicated by object 
        batteryAlarmHighTemperature.  In such a case, a 
        batteryTemperatureNotification can be generated that not 
        only indicates the battery for which the temperature limit 
        has been exceeded but also the particular cell.
        
        The initial value of this object is the empty string.  The 
        value of this object is set each time a
        batteryLowNotification, batteryTemperatureNotification,
        batteryCriticalNotification, or batteryAgingNotification 
        is generated.
        
        When a notification is generated that does not indicate a 
        specific cell or set of cells, the value of this object is
        set to the empty string." 
    ::= { batteryEntry 25 }



--==================================================================
-- 2.  Notifications
--==================================================================

batteryChargingStateNotification NOTIFICATION-TYPE
    OBJECTS     { 
        batteryChargingOperState 
    }
    STATUS      current
    DESCRIPTION
        "This notification can be generated when a charging state
        of the battery (indicated by the value of object
        batteryChargingOperState) is triggered by an event other 
        than a write action to object batteryChargingAdminState.
        Such an event may, for example, be triggered by a local
        battery controller."
    ::= { batteryNotifications 1 }

batteryLowNotification NOTIFICATION-TYPE
    OBJECTS     { 
        batteryActualCharge, 
        batteryActualVoltage,
        batteryCellIdentifier        
    }
    STATUS      current
    DESCRIPTION
        "This notification can be generated when the current charge
        (batteryActualCharge) or the current voltage 
        (batteryActualVoltage) of the battery falls below a 
        threshold defined by object batteryAlarmLowCharge or object 
        batteryAlarmLowVoltage, respectively. 
        
        Note that, typically, this notification is generated in a 
        state where the battery is still sufficiently charged to keep
        the device(s) that it powers operational for some time. 
        If the charging state of the battery has become critical, 
        i.e., the device(s) powered by the battery must go to a 
        'sleep' or 'off' state, then the batteryCriticalNotification 
        should be used instead.
        
        If the low charge or voltage has been detected for a single 
        cell or a set of cells of the battery and not for the entire
        battery, then object batteryCellIdentifier should be set to
        a value that identifies the cell or set of cells.  
        Otherwise, the value of object batteryCellIdentifier should
        be set to the empty string when this notification is 
        generated.

        The notification should not be sent again for the same 
        battery or cell before either (a) the current voltage or 
        the current charge, respectively, has become higher than the
        corresponding threshold through charging or (b) an indication
        of a maintenance action has been detected, such as a battery 
        disconnection event or a reinitialization of the battery 
        monitoring system.
        
        This notification should not be sent when the battery is in
        a charging mode, i.e., the value of object 
        batteryChargingOperState is charging(2)."
    ::= { batteryNotifications 2 }

batteryCriticalNotification NOTIFICATION-TYPE
    OBJECTS     { 
        batteryActualCharge, 
        batteryActualVoltage,
        batteryCellIdentifier        
    }
    STATUS      current
    DESCRIPTION
        "This notification can be generated when the current charge
        of the battery falls so low that it cannot provide a 
        sufficient power supply function for regular operation
        of the powered device(s).  The battery needs to be charged 
        before it can be used for regular power supply again.  The 
        battery may still provide sufficient power for a 'sleep' 
        mode of a powered device(s) or for a transition into an 'off' 
        mode.
                
        If the critical state is caused by a single cell or a set of 
        cells of the battery, then object batteryCellIdentifier 
        should be set to a value that identifies the cell or set of
        cells.  Otherwise, the value of object batteryCellIdentifier
        should be set to the empty string when this notification is
        generated.

        The notification should not be sent again for the same 
        battery before either the battery charge has increased 
        through charging to a non-critical value or an indication 
        of a maintenance action has been detected, such as a battery 
        disconnection event or a reinitialization of the battery 
        monitoring system.

        This notification should not be sent when the battery is in
        a charging mode, i.e., the value of object 
        batteryChargingOperState is charging(2)."        
    ::= { batteryNotifications 3 }
    
batteryTemperatureNotification NOTIFICATION-TYPE
    OBJECTS     { 
        batteryTemperature,
        batteryCellIdentifier 
    }
    STATUS      current
    DESCRIPTION
        "This notification can be generated when the measured
        temperature (batteryTemperature) rises above the threshold
        defined by object batteryAlarmHighTemperature or falls 
        below the threshold defined by object 
        batteryAlarmLowTemperature.
        
        If the low or high temperature has been detected for a 
        single cell or a set of cells of the battery and not for the
        entire battery, then object batteryCellIdentifier should be
        set to a value that identifies the cell or set of cells.
        Otherwise, the value of object batteryCellIdentifier should
        be set to the empty string when this notification is 
        generated.
        
        It may occur that the temperature alternates between values
        slightly below and slightly above a threshold.  For limiting 
        the notification rate in such a case, this notification 
        should not be sent again for the same battery or cell, 
        respectively, within a time interval of 10 minutes. 
        
        An exception to the rate limitations occurs immediately 
        after the reinitialization of the battery monitoring system. 
        At this point in time, if the battery temperature is above 
        the threshold defined by object batteryAlarmHighTemperature
        or below the threshold defined by object 
        batteryAlarmLowTemperature, respectively, then this 
        notification should be sent, independent of the time at 
        which previous notifications for the same battery or cell, 
        respectively, had been sent."
    ::= { batteryNotifications 4 }

batteryAgingNotification NOTIFICATION-TYPE
    OBJECTS     { 
        batteryActualCapacity, 
        batteryChargingCycleCount,
        batteryCellIdentifier 
    }
    STATUS      current
    DESCRIPTION
        "This notification can be generated when the actual
        capacity (batteryActualCapacity) falls below a threshold
        defined by object batteryAlarmLowCapacity 
        or when the charging cycle count of the battery 
        (batteryChargingCycleCount) exceeds the threshold defined 
        by object batteryAlarmHighCycleCount.
        
        If the aging has been detected for a single cell or a set
        of cells of the battery and not for the entire battery, then 
        object batteryCellIdentifier should be set to a value that
        identifies the cell or set of cells.  Otherwise, the value
        of object batteryCellIdentifier should be set to the empty
        string when this notification is generated.
        
        This notification should not be sent again for the same 
        battery or cell, respectively, before an indication of a 
        maintenance action has been detected, such as a battery 
        disconnection event or a reinitialization of the battery
        monitoring system."
    ::= { batteryNotifications 5 }

batteryConnectedNotification NOTIFICATION-TYPE
    OBJECTS     { 
        batteryIdentifier 
    }
    STATUS      current
    DESCRIPTION
        "This notification can be generated when it has been 
        detected that a battery has been connected.  The battery
        can be identified by the value of object batteryIdentifier
        as well as by the value of index entPhysicalIndex that is 
        contained in the OID of object batteryIdentifier."
    ::= { batteryNotifications 6 }

batteryDisconnectedNotification NOTIFICATION-TYPE
    STATUS      current
    DESCRIPTION
        "This notification can be generated when it has been 
        detected that one or more batteries have been disconnected."
    ::= { batteryNotifications 7 }

    
--==================================================================
-- 3.  Conformance Information
--==================================================================

batteryCompliances OBJECT IDENTIFIER ::= { batteryConformance 1 }
batteryGroups      OBJECT IDENTIFIER ::= { batteryConformance 2 }

--------------------------------------------------------------------
-- 3.1.  Compliance Statements
--------------------------------------------------------------------

batteryCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for implementations of the
        BATTERY-MIB module.

        A compliant implementation MUST implement the objects
        defined in the mandatory groups batteryDescriptionGroup
        and batteryStatusGroup.
        
        Note that this compliance statement requires
        compliance with the entity4CRCompliance
        MODULE-COMPLIANCE statement of the
        ENTITY-MIB (RFC 6933)."
    MODULE  -- this module
        MANDATORY-GROUPS { 
            batteryDescriptionGroup,
            batteryStatusGroup
        }
        
        GROUP   batteryAlarmThresholdsGroup
        DESCRIPTION
           "A compliant implementation does not have to implement
            the batteryAlarmThresholdsGroup."
            
        GROUP   batteryNotificationsGroup
        DESCRIPTION
           "A compliant implementation does not have to implement
            the batteryNotificationsGroup."
            
        GROUP   batteryPerCellNotificationsGroup
        DESCRIPTION
           "A compliant implementation does not have to implement
            the batteryPerCellNotificationsGroup."
            
        GROUP   batteryAdminGroup
        DESCRIPTION
           "A compliant implementation does not have to implement
            the batteryAdminGroup."
        
        OBJECT batteryAlarmLowCharge
        MIN-ACCESS  read-only
        DESCRIPTION
            "A compliant implementation is not required 
            to support set operations on this object."

        OBJECT batteryAlarmLowVoltage
        MIN-ACCESS  read-only
        DESCRIPTION
            "A compliant implementation is not required 
            to support set operations on this object."

        OBJECT batteryAlarmLowCapacity
        MIN-ACCESS  read-only
        DESCRIPTION
            "A compliant implementation is not required 
            to support set operations on this object."

        OBJECT batteryAlarmHighCycleCount
        MIN-ACCESS  read-only
        DESCRIPTION
            "A compliant implementation is not required 
            to support set operations on this object."

        OBJECT batteryAlarmHighTemperature
        MIN-ACCESS  read-only
        DESCRIPTION
            "A compliant implementation is not required 
            to support set operations on this object."

        OBJECT batteryAlarmLowTemperature
        MIN-ACCESS  read-only
        DESCRIPTION
            "A compliant implementation is not required 
            to support set operations on this object."

    ::= { batteryCompliances 1 }

--------------------------------------------------------------------
-- 3.2.  MIB Grouping
--------------------------------------------------------------------

batteryDescriptionGroup OBJECT-GROUP
    OBJECTS {
       batteryIdentifier,
       batteryFirmwareVersion,
       batteryType,
       batteryTechnology,
       batteryDesignVoltage,
       batteryNumberOfCells,
       batteryDesignCapacity,
       batteryMaxChargingCurrent,
       batteryTrickleChargingCurrent
    }
    STATUS      current
    DESCRIPTION
       "A compliant implementation MUST implement the objects
       contained in this group."
    ::= { batteryGroups 1 }

batteryStatusGroup OBJECT-GROUP
    OBJECTS {
       batteryActualCapacity,
       batteryChargingCycleCount,
       batteryLastChargingCycleTime,
       batteryChargingOperState,
       batteryActualCharge,
       batteryActualVoltage,
       batteryActualCurrent,
       batteryTemperature
    }
    STATUS      current
    DESCRIPTION
       "A compliant implementation MUST implement the objects
       contained in this group."
    ::= { batteryGroups 2 }

batteryAdminGroup OBJECT-GROUP
    OBJECTS {
       batteryChargingAdminState
    }
    STATUS      current
    DESCRIPTION
       "A compliant implementation does not have to implement the 
       object contained in this group."
    ::= { batteryGroups 3 }

batteryAlarmThresholdsGroup OBJECT-GROUP
    OBJECTS {
       batteryAlarmLowCharge,
       batteryAlarmLowVoltage,
       batteryAlarmLowCapacity,
       batteryAlarmHighCycleCount,
       batteryAlarmHighTemperature,
       batteryAlarmLowTemperature
    }
    STATUS      current
    DESCRIPTION
       "A compliant implementation does not have to implement the 
       objects contained in this group."
    ::= { batteryGroups 4 }

batteryNotificationsGroup NOTIFICATION-GROUP
    NOTIFICATIONS {
       batteryChargingStateNotification,
       batteryLowNotification,
       batteryCriticalNotification,
       batteryAgingNotification,
       batteryTemperatureNotification,
       batteryConnectedNotification,
       batteryDisconnectedNotification
    }
    STATUS      current
    DESCRIPTION
        "A compliant implementation does not have to implement the 
        notifications contained in this group."
    ::= { batteryGroups 5 }

batteryPerCellNotificationsGroup OBJECT-GROUP
    OBJECTS {
       batteryCellIdentifier
    }
    STATUS      current
    DESCRIPTION
        "A compliant implementation does not have to implement the 
        object contained in this group."
    ::= { batteryGroups 6 }
END]]></artwork></figure>

    </section>

    <section title="Security Considerations">

<!--Begin DNE text  -->      
      <t>There are a number of management objects defined in this MIB 
      module with a MAX-ACCESS clause of read-write.  Such objects may 
      be considered sensitive or vulnerable in some network environments.  
      The support for SET operations in a non-secure environment without 
      proper protection opens devices to attack.  
      These are the tables and objects and their sensitivity/vulnerability:
      </t>
<!--End DNE text  --> 
      <t><list style="symbols">
        <t>batteryChargingAdminState:<vspace/>
        Setting the battery charging state can be beneficial for an operator
        for various reasons such as charging batteries when the price of
        electricity is low. However, setting the charging state can be used by
        an attacker to discharge batteries of devices and thereby switching
        these devices off if they are powered solely by batteries. In particular,
        if the batteryAlarmLowCharge and batteryAlarmLowVoltage can also be
        set, this attack will go unnoticed (i.e., no notifications
        are sent).</t>
      </list></t>
      
      <t><list style="symbols">
        <t>batteryAlarmLowCharge and batteryAlarmLowVoltage:<vspace/>
        These objects set the threshold for an alarm to be raised when
        the battery charge or voltage falls below the corresponding one
        of them.  An attacker setting one of these alarm values can 
        switch off the alarm by setting it to the 'off' value 0, or it can modify 
        the alarm behavior by setting it to any other value.  The result 
        may be loss of data if the battery runs empty without warning 
        to a recipient expecting such a notification.</t>
      </list></t>

      <t><list style="symbols">
        <t>batteryAlarmLowCapacity and batteryAlarmHighCycleCount:<vspace/>
        These objects set the threshold for an alarm to be raised when
        the battery becomes older and less performant than required for
        stable operation.  An attacker setting this alarm value can 
        switch off the alarm by setting it to the 'off' value 0 or 
        modify the alarm behavior by setting it to any other value.  
        This may lead to either a costly replacement of
        a working battery or use of batteries that are too old or too weak. 
        The consequence of the latter could be that, e.g., a battery 
        cannot provide power long enough between two scheduled charging
        actions causing the powered device to shut down and potentially
        lose data.</t>
      </list></t>

      <t><list style="symbols">
        <t>batteryAlarmHighTemperature and batteryAlarmLowTemperature:<vspace/>
        These objects set thresholds for an alarm to be raised when
        the battery rises above / falls below them.  An attacker setting one of
        these alarm values can switch off these alarms by setting them to the 
        'off' value '7fffffff'H, or it can modify the alarm behavior by setting 
        them to any other value.  The result may be, e.g., an unnecessary 
        shutdown of a device if batteryAlarmHighTemperature is set too low,
        there is damage to the device by temperatures that are too high if switched off or set to 
        values that are too high, or there is damage to the battery when, e.g., it is being
        charged. Batteries can also be damaged, e.g., in an attempt to charge them
        at temperatures that are too low. </t>
      </list></t>

<!--Begin DNE text  --> 
      <t>Some of the readable objects in this MIB module (i.e., objects with a
      MAX-ACCESS other than not-accessible) may be considered sensitive or
      vulnerable in some network environments. It is thus important to control
      even GET and/or NOTIFY access to these objects and possibly to even
      encrypt the values of these objects when sending them over the network
      via SNMP. These are the tables and objects and their
      sensitivity/vulnerability:</t>
<!--End DNE text  --> 
      <t>All potentially sensible or vulnerable objects of this
      MIB module are in the batteryTable.  In general, there are
      no serious operational vulnerabilities foreseen in case of an
      unauthorized read access to this table. However, corporate confidentiality
      issues need to be considered. The following information or parts of it might be a trade secret:
      <list style="symbols">
        <t>the number of batteries installed in a managed node (batteryIndex)</t>

        <t>properties of these batteries (batteryActualCapacity and 
        batteryChargingCycleCount)</t>

        <t>the time at which the next replacement cycle for batteries can be expected
        (batteryAlarmLowCapacity and batteryAlarmHighCycleCount)</t>

        <t>the types of batteries in use and their firmware versions
        (batteryIdentifier, batteryFirmwareVersion, batteryType, and 
        batteryTechnology)</t>
      </list></t>
      
      <t>For any battery-powered device whose use can be correlated to an 
      individual or a small group of individuals, the following objects 
      have the potential to reveal information about those individuals' 
      activities or habits (e.g., if they are near a power outlet, if 
      they have been using their devices heavily, etc.):
      <list style="symbols">
        <t>batteryChargingCycleCount</t>
        <t>batteryLastChargingCycleTime</t>
        <t>batteryChargingOperState</t>
        <t>batteryActualCharge</t>
        <t>batteryActualVoltage</t>
        <t>batteryActualCurrent</t>
        <t>batteryTemperature</t>
        <t>batteryAlarmLowCharge</t>
        <t>batteryAlarmLowVoltage</t>
        <t>batteryAlarmLowCapacity</t>
        <t>batteryAlarmHighCycleCount</t>
        <t>batteryAlarmHighTemperature</t>
        <t>batteryAlarmLowTemperature</t>
      </list></t>

      <t>Implementers of this specification should use appropriate
      privacy protections as discussed in Section 9 of
      <xref target="RFC6988">"Requirements for Energy Management"</xref>.
      Battery monitoring of devices used by individuals or 
      in homes should only occur with proper authorization.</t>

<!--Begin DNE text  --> 
      <t>SNMP versions prior to SNMPv3 did not include adequate 
      security.  Even if the network itself is secure (for example 
      by using IPsec), there is no control as to who on the secure 
      network is allowed to access and GET/SET (read/change/create/delete)
      the objects in this MIB module.</t>

      <t>Implementations SHOULD provide the security features 
      described by the  SNMPv3 framework (<xref target="RFC3410">see</xref>), 
      and implementations claiming compliance to the SNMPv3 standard MUST
      include full support for authentication and privacy via the 
      <xref target="RFC3414">User-based Security Model (USM)</xref> with the 
      <xref target="RFC3826">AES cipher algorithm</xref>. Implementations 
      MAY also provide support for the 
      <xref target="RFC5591">Transport Security Model (TSM)</xref> in 
      combination with a secure transport such as 
      <xref target="RFC5592">SSH</xref> 
      or <xref target="RFC6353">TLS/DTLS</xref>.</t>

      <t>Further, deployment of SNMP versions prior to SNMPv3 is NOT
      RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to
      enable cryptographic security.  It is then a customer/operator
      responsibility to ensure that the SNMP entity giving access to an
      instance of this MIB module is properly configured to give access to
      the objects only to those principals (users) that have legitimate
      rights to indeed GET or SET (change/create/delete) them.</t>

<!--End DNE text  --> 
    </section>

    <section title="IANA Considerations">

      <section title="SMI Object Identifier Registration">
        <t>The Battery MIB module defined in this document uses the 
        following IANA-assigned OBJECT IDENTIFIER value recorded in 
        the SMI Numbers registry:

        <figure>
          <artwork><![CDATA[
          Descriptor        OBJECT IDENTIFIER value
          ----------        -----------------------
          batteryMIB        { mib-2 233 }
        ]]></artwork>
        </figure>
        </t>

     
      </section>

      <section title="Battery Technology Registration">

        <t>Object batteryTechnology defined in 
        <xref target="definitions"/> reports battery technologies. 
        Eighteen values for battery technologies have initially been
        defined. They are listed in a table in 
        <xref target="technologies"/>.</t>
      
        <t>For ensuring extensibility of this list, IANA has 
        created a registry for battery technologies at 
        &lt;http://www.iana.org/assignments/battery-technologies&gt; 
        and filled it with the initial list given in 
        <xref target="technologies"/>.</t>

        <t>New assignments of numbers for battery technologies 
        will be administered by IANA through  Expert Review 
        <xref target="RFC5226"/>. Experts must check for 
        sufficient relevance of a battery technology to be added
        according to the guidelines in 
        <xref target="iana-guidelines"/>.</t>
        
      </section>

    </section>

  
  </middle>

  <back>
<!--[rfced] May we sort the normative and informative references to be
in alphabetical order?
-->

    <references title="Normative References">
      &rfc2119;

      &rfc5226;

      &rfc2578;

      &rfc2579;

      &rfc2580;

      &rfc3411;

      &rfc3414;
            
      &rfc3826;

      &rfc5591;

      &rfc5592;

      &rfc6353;

      &rfc6933;
    </references>

    <references title="Informative References">
      &rfc6988;

      &rfc7326;
      
      &rfc7460;

      &rfc1628;

      &rfc3410;
            
      <reference anchor='SBS'>
        <front>
            <title>Smart Battery Data Specification</title>
            <author></author>
            <date month='December' year='1998' />
        </front>
        <seriesInfo name='Revision' value='1.1' />
    </reference>
    
    </references>

  <section title="Acknowledgements" numbered="no">
      <t>We would like to thank Steven Chew, Bill Mielke, and 
      Alan Luchuk for their valuable input.</t>
    </section>